Mitsubishi MELSEC-Q EQ-V680D1 User Manual page 115

Rfid interface module
Table of Contents

Advertisement

6. HOW TO COMMUNICATE WITH ID TAGS
6.4.9 Check data
6 - 47
The Check Data program is a program for checking if an error occurred in the data of
an ID tag. The program writes data and data check code to the ID tag.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Command code specification
U0 \ G0
area (CH1)
Head address specification
U0 \ G3
area (CH1)
Number of processed points
U0 \ G4
specification area (CH1)
(b) Devices used by user
1. External inputs (commands/data)
Device
M1080
Check Data of ID Tag command
M1081
Cancel Check Data of ID Tag command
2. External outputs (verification)
Device
M1082
Normal completion during Check Data of ID Tag
M1083
Module error during Check Data of ID Tag
D1080
Error details storage during Check Data of ID Tag
Buffer Memory Name
Application
Application
Setting Contents
H7 (Check Data)
K10 (Address: 0)
K10 (10 bytes)
6 - 47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q eq-v680d2

Table of Contents