6. HOW TO COMMUNICATE WITH ID TAGS
6.4.11 Copy
6 - 53
The Copy program is a program for copying data of an ID tag between Channel 1 and
Channel 2.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Command code specification
U0 \ G0
area (CH1)
Head address specification
U0 \ G3
area (CH1)
Number of processed points
U0 \ G4
specification area (CH1)
Command option specification
U0 \ G5
area (CH1)
(b) Devices used by user
1. External inputs (commands/data)
Device
M1100
Copy Between ID Tags command
M1101
Cancel Copy Between ID Tags command
2. External outputs (verification)
Device
M1102
Normal completion during Copy Between ID Tags
M1103
Module error during Copy Between ID Tags
D1100
Error details storage during Copy Between ID Tags
Buffer Memory Name
Application
Application
Setting Contents
H9 (Copy)
K10 (Copy source head address: 10)
K100 (100 bytes)
K110 (Copy destination head address:
110)
6 - 53