Mitsubishi MELSEC-Q EQ-V680D1 User Manual page 108

Rfid interface module
Table of Contents

Advertisement

6. HOW TO COMMUNICATE WITH ID TAGS
6.4.7 Write calculation
6 - 40
The Write Calculation program is a program for writing the calculation result (data) of
an addition or subtraction operation performed with ID tag data.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Command code specification
U0 \ G0
area (CH1)
Head address specification
U0 \ G3
area (CH1)
Number of processed points
U0 \ G4
specification area (CH1)
Command option specification
U0 \ G5
area (CH1)
(b) Devices used by user
1. External inputs (commands/data)
Device
M1060
Write Calculation of ID Tag command
M1061
Write Calculation of ID Tag result reception
M1062
Cancel Write Calculation of ID Tag command
2. External outputs (verification)
Device
M1063
Normal completion during Write Calculation of ID Tag
M1064
Module error during Write Calculation of ID Tag
M1065
ID communication complete during Write Calculation of ID Tag
D1060
Error details storage during Write Calculation of ID Tag
D1061 to D1062
Calculation result storage during Write Calculation of ID Tag
Buffer Memory Name
Application
Application
Setting Contents
H5 (Write Calculation)
K10 (Address: 10)
K4 (4 bytes)
K1 (Addition data 1)
6 - 40

Hide quick links: