Mitsubishi MELSEC-Q EQ-V680D1 User Manual page 122

Rfid interface module
Table of Contents

Advertisement

6. HOW TO COMMUNICATE WITH ID TAGS
6 - 54
(2) Program example
Initialize output devices
M1100
Copy
command
ID instruction execution
M1100
X0
X2
Module
Copy
CH1 ID
ready
command
communication
complete
End processing / Cancel processing
M1101
X0
X3
Cancel
CH.1 ID
Module
Copy
-BUSY
ready
command
X4
CH1 ID
communi
-cation
complete
X5
CH1 error
detection
X3
X4
X5
CH.1 ID
CH1 ID
CH1 error
-BUSY
instruction
detection
complete
RST
M1102
Copy norma
completion
RST
M1103
Module error
during Copy
MOV
K0
D1100
Error details
during Copy
<Command code specification
U0\
MOV
H9
G0
<Head address specification
U0\
MOV
K10
G3
<Number of processed bytes specification >
U0\
MOV
K100
G4
<Command option specification
U0\
MOV
K110
G5
SET
Y14
CH1 ID
instruction
execution
request
RST
M1100
Copy
command
RST
Y14
CH1 ID
instruction
execution
request
RST
M1101
Cancel
Copy
command
RST
Y14
CH1 ID
instruction
execution
request
6 - 54
>
>
>