Mitsubishi MELSEC-Q EQ-V680D1 User Manual page 141

Rfid interface module
Table of Contents

Advertisement

6. HOW TO COMMUNICATE WITH ID TAGS
6 - 73
(4) Program conditions
(a) Setting contents
Intelligent
Function Module
Device Address
Command code specification
U0 \ G0
area (CH1)
Communication specification
U0 \ G1
area (CH1)
Processing specification area
U0 \ G2
(CH1)
Head address specification
U0 \ G3
area (CH1)
No. of processing points
U0 \ G4
specification area (CH1)
(b) Devices used by user
1. External inputs (commands)
Device
M1010
Read ID Tag command
M1020
Write to ID Tag command
2. External outputs (verification)
Device
D1200 to D1203
Read data storage during Read ID tag
D1020
Error details storage
Buffer Memory Name
Setting Contents
Read
H0 (Read)
H1 (Write)
K0 (Trigger)
K0 (Data storage order: Upper -> lower
Calculation method: Addition
Calculation/Verification: Calculation)
K10
K20
(Address: 10)
(Address: 20)
K8 (8 bytes)
Application
Application
Write
6 - 73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q eq-v680d2

Table of Contents