6. HOW TO COMMUNICATE WITH ID TAGS
6 - 41
(2) Program example
Initialize output devices
M1060
Write
Calculation
command
ID instruction execution
M1060
X0
X2
Write
CH1 ID
Module
Calculation
communication
ready
command
complete
X3
X4
X5
CH.1 ID
CH1 error
CH1 ID
-BUSY
detection
instruction
complete
RST
M1063
Write
Calculation
normal
completion
RST
M1064
Module error
during Write
Calculation
RST
M1065
Write
Calculation ID
communication
complete
MOV
K0
D1060
Error details
during Write
Calculation
<Command code specification
U0\
MOV
H5
G0
<Head address specification
U0\
MOV
K10
G3
<Number of processed points specification >
U0\
MOV
K4
G4
<Command option specification
U0\
MOV
K1
G5
SET
Y14
CH1 ID
instruction
execution
request
RST
M1060
Write
Calculation
command
6 - 41
>
>
>