Resampling a song to create a Wave file

You can record a completed Song to a stereo WAVE 
file, and then burn that WAVE file to an audio CD 
using the internal CD‐R/RW drive. For more 
information, see "Creating and playing audio CDs" on 
page 181.
1. In Sequencer mode, select the song from which 
you want to create a WAVE file.
Either create a song, or use Disk mode to load a 
previously‐created song.
A maximum of 80 minutes for either mono or stereo 
can be written to media in one sampling operation 
(mono: approximately 440 MB, stereo: 
approximately 879 MB).
2. Access the Sequencer P0: Play/REC– Audio 
Input/Sampling page.
3. We will be modifying the Audio Input settings, so 
turn the Input "Use Global Setting" off.
4. Choose the Auto HDR/Sampling Setup page menu 
command.
A dialog box will appear.
5. Choose "2ch Mix to Disk."
6. Press the OK button to execute the command.
Preparations for In‐Track Sampling are now 
complete.
– Audio Input –
INPUT1–4, S/P DIF L, R
Bus Select (IFX/Indiv.): Off
REC Bus: Off
Turn off all input from INPUT 1–4 and S/P DIF L, R.
– RECORDING LEVEL–
Recording Level: 0.0
This is the default setting for resampling.
– Sampling Setup –
Source Bus: L/R
The sound sent to L/R bus will be sampled.
"Trigger": Sequencer START SW
Press the SAMPLING REC switch and START/STOP 
Sampling in Program, Combination, and Sequencer modes
switch to enter record‐standby mode. Then press 
the SEQUENCER START/STOP switch to start 
recording.
Save to: DISK
The sample will be saved on the media you 
specified in "Select Directory."
Mode: Stereo
The sound of the internal L/R channels will be 
sampled in stereo.
7. Select the page menu command Select Directory, 
and specify the destination to which the WAVE 
file will be written.
Use "Drive Select" and the Open and Up buttons to 
select the directory in which the WAVE file will be 
saved.
Press the text edit button to access the text edit 
dialog box, and input a filename (up to six 
characters).
Leave Take No. checked. The number at the right of 
Take No. will be input as the last two characters of 
the filename.
This number will increment each time you sample, 
ensuring that the filename will not be the same even 
if you sample repeatedly.
After you have made the settings, press the Done 
button to close the dialog box.
8. Set Sample Time to the length that you want to 
sample.
Set this to a length slightly greater than the length of 
the song.
9. Set the recording level.
Press the SAMPLING REC switch.
Note: It will take between several seconds to nearly a 
minute from the moment you press the SAMPLING 
REC switch until the OASYS enters standby mode 
(i.e., until the SAMPLING REC switch changes from 
blinking to lit). This time is required in order to 
allocate sufficient space on the disk.
Press the SEQUENCER START/STOP switch to play 
back the song, and adjust the sampling volume 
while you watch the level meters. The default 
setting is 0.0 dB. If the level is too low, use the 
VALUE controller to raise the level as high as 
possible without causing the "CLIP !" indicator to 
appear.
When you finish making adjustments, press the 
SAMPLING REC switch.
Press the SEQUENCER START/STOP switch to stop 
the song playback. Then press the LOCATE switch.
10.Start sampling.
Press the SAMPLING REC switch and then the 
SAMPLING START/STOP switch to enter 
recording‐standby mode.
Press the SEQUENCER START/STOP switch to play 
back the song. Sampling will begin at the same time.
When the song finishes playing back, press the 
SAMPLING START/STOP switch to stop sampling.
Use the page menu command "Select Directory" to 
verify that the WAVE file was created. Select the file 
149