Sampling In Sequencer Mode - Korg Oasys Operation Manual

Open architecture synthesis studio
Hide thumbs Also See for Oasys:
Table of Contents

Advertisement

Creating songs (Sequencer mode)
Key 1 on
Key 2 on
Song
Patterns 1 and 2 are set to
Mode=Manual, and have
identical Sync settings
Sync: Off
Pattern 1
Pattern 2
Sync: Beat
Pattern 1
Pattern 2
Sync: Measure
Pattern 1
Pattern 2
Sync: SEQ
Pattern 1
Pattern 2
3. Select the P0: Play/REC– MIDI Track Prog 
Select/Mixer page.
4. Check the "RPPR" check box, and set "Track 
Select" to MIDI Track 02.
When the RPPR function is on, pressing a key to 
which a pattern is assigned will cause the assigned 
pattern to start playing, regardless of the track that's 
selected in "Track Select."
Keys to which patterns are not assigned can be 
played in the usual way. You can play the program 
that's assigned to the MIDI track you select here.
5. Since you want the tracks you play via RPPR and 
the track you play from the keyboard to be 

Sampling in Sequencer mode

Sampling is still available in Sequencer mode ‐ which 
can be very convenient. The main areas of functionality 
are summarized below. For more information, see 
"Examples of sampling in Sequencer mode" on 
page 147.
• Multisample etc. you create can be played back in 
Sequencer mode together with internal programs. 
The Time Slice function of Sampling mode lets you 
divide up a rhythm loop sample, and create 
playback data that triggers the divided samples at 
120
Sync settings
Key 1 off
recorded at the same time, check the Multi REC 
check box.
Note: If Recording Setup is set to "Loop All Tracks," 
it will not be possible to select Multi REC. Set the 
Recording Setup to Overwrite.
6. Press the SEQUENCER REC/WRITE switch to 
enter record‐ready mode.
7. For the tracks you will be recording (MIDI Track 1, 
2), press Play/Rec/Mute to make them indicate 
REC.
Make sure that the tracks you're not recording are 
indicated as Play or Mute.
8. Press the LOCATE switch to set the location to 
001:01.000.
9. Press the SEQUENCER START/STOP switch, and 
then press a key that plays an RPPR pattern.
If, during the pre‐count before recording, you press 
a key that's assigned to an RPPR pattern, the pattern 
will begin playing (and being recorded) the moment 
that recording begins.
Record the RPPR pattern playback and keyboard 
performance.
When recording the playback of patterns triggered 
by RPPR, the timing of the recorded events may be 
slightly skewed. If this occurs, try setting "REC 
Resolution" to a setting other than Hi.
10.When you are finished performing, press the 
SEQUENCER START/STOP switch.
Recording will end, and the sequencer will return to 
the location at which recording began.
If you made a mistake during your performance or 
would like to re‐record, you can use the Compare 
function (press the COMPARE switch) to re‐record 
as many times as you wish.
11.If you want to record other tracks, un‐check the 
Multi REC (See step 5) or "RPPR" (See step 4) 
check boxes as necessary.
the appropriate timing. You can play back this 
performance data in Sequencer mode, and adjust 
the playback tempo without affecting the pitch of 
the rhythm loop sample. You can even exchange 
the note numbers of the performance data or 
change its timing to transform the original rhythm 
loop sample into a completely new rhythm loop.
• The In‐Track Sampling function lets you sample an 
external audio source that's playing along with the 

Hide quick links: