How Sampling Mode Is Organized; Samples And Multisamples - Korg Oasys Operation Manual

Open architecture synthesis studio
Hide thumbs Also See for Oasys:
Table of Contents

Advertisement

Sampling (Open Sampling System)
2) You can sample external audio sources via the 
OASYS' input jacks (see "Sampling mode" 1 and 2, 
above). At this time, you can mix the OASYS' own 
performance with the audio signals from the external 
source and sample the combined result, or you can 
monitor the performance of the OASYS while 
sampling only the external source from the input jacks.
3) In Sequencer mode when you sample an external 
audio source that's playing along with the song 
playback, note data will be automatically created in a 
track to trigger this sample at the appropriate moment 
in the song. This means that you can sample your vocal 
or guitar performance while playing back the 
sequencer. This is called the In‐Track Sampling 
function.
Sampling frequency and bit resolution
As shown in the diagram, sampling reads the level of 
the analog signal at fixed intervals along the time axis, 
and stores the levels in memory as digital data.
Level
Analog waveform
Level
Sampled digital
waveform
The "fixed intervals" mentioned above are generally 
expressed as the "sampling frequency." 48 kHz 
(kilohertz) means that sampling is performed 48,000 
times each second, and that the interval is 1 
(second)/48,000 (times) = approximately 0.00002083 
(seconds) = approximately 0.02083 mS (millisecond).
The higher the sampling frequency is, the closer to the 
original analog signal the waveform in memory will 
be.
Conceptual diagram of the Open Sampling System
Analog/digital
AUDIO INPUT jack
convertor
Analog signal
ADC
CD-R/RW Drive Audio Input
(Audio CD)
Analog signal
Used by combinations
and songs
124
Time
48 kHz
= 48,000 times every second
= 0.0208 mS cycle
16 bit
= 65,536 levels
Time
of data
Resampling
Program,
combinations and
Insert Effects
songs
(Master Effects)
Digital signal
(Ripping)
Program
Each level is read, and converted into digital data. The 
accuracy at this time is determined by the bit 
resolution. This process converts an analog signal with 
infinite resolution into a digital signal with finite 
resolution. With 16 bit resolution, each level is 
indicated in 65,536 steps (the sixteenth power of two).
The greater the bit resolution is, the closer to the 
original analog signal the waveform in memory will 
be.
48 kHz 16 bit sampling is the same quality as in audio 
devices such as DAT. A CD uses 44.1 kHz 16 bit 
sampling, which is a slightly lower sampling 
frequency.

How Sampling mode is organized

This section describes how sampling on the OASYS is 
organized. (See the diagram below)

Samples and Multisamples

Samples
The data that is recorded (sampled) into internal 
memory or loaded from a file is referred to as a sample 
or sample file. Samples consist of the actual waveform 
data, and parameters that specify how the data will be 
played back, such as Start, Loop Start, and End 
Address. Samples can be used in multisamples and 
drum kits.
The OASYS can hold a maximum of 4,000 samples in 
its internal memory.
The OASYS can share a single waveform among 
multiple samples. This allows you to create multiple 
samples with different playback addresses from the 
same waveform without wasting internal memory. For 
example, suppose that you have waveform data that 
records a voice saying "One‐Two‐Three." This single 
piece of waveform data could be shared by three 
samples, with the playback of sample A producing 
"One‐Two‐Three," sample B producing "One‐Two," 
and sample C producing "Two‐Three." 
For more information, see "Copy" on page 681 of the 
Parameter Guide.
RAM (memory):
Digital/analog
convertor
Digital signal
DAC
Sample 0000 ... 3999
Disk
Multisample 000 ... 999
RAM (internal memory)
AUDIO
OUTPUT
jack
Analog signal
WAVE File

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents