Multisamples
Multisamples lay out one or more Samples across the 
keyboard. For instance, a very simple guitar 
Multisample might have six Samples–one for each 
string.
Each Sample is contained in an Index, which includes 
parameters for the key range, original Sample pitch, 
tuning, level, and so on.
Multisamples can have up to 128 Indexes.
Using multisamples
When sampling an instrument that is able to produce a 
wide range of pitches, such as a piano, recording just 
one sample and applying it (playing it back) over the 
entire pitch range will not produce a natural‐sounding 
result. By using a multisample you can record separate 
samples for each pitch range, and assign these samples 
to their respective pitch ranges to avoid any unnatural 
sounds during playback.
All of the instrumental sounds in the OASYS's internal 
preset multisamples are constructed in this way. For 
example, you might record one sample per octave, and 
assign each of these samples to an index (keyboard 
area). 
By assigning multiple samples such as phrase samples 
or rhythm loops to a multisample and arranging them 
across the keyboard, you can play multiple samples 
simultaneously. You can assign different phrases to 

Preparations for sampling

Audio input settings

Input/Audio input
Input 1...4, S/P DIF L, S/P DIF R
Input 1...4: These are the input settings for analog 
audio devices connected to the INPUT 1–4 jacks.
The INPUT 1 and 2 jacks provide both XLR and 1/4" 
TRS balanced connectors. They can accept either mic‐
level or line‐level signals.
Set the MIC/LINE switch appropriately for the device 
that's connected, and use the LEVEL knob to adjust the 
gain.
Choose the LINE setting (switch in the inward 
position) if you've connected a mixer, computer, audio 
system, signal processor, or another sequencer.
Choose the MIC setting (switch in the outward 
position) if you've connected a mic. If you are using a 
condenser mic that requires phantom power, turn the 
PHANTOM POWER switch on. Otherwise, leave this 
switch off.
Never connect an unbalanced instrument, device, or 
mic to the XLR jacks when phantom power is 
turned on.
The INPUT 3 and 4 jacks can only input line‐level 
signals from instruments or other devices. These are 
unbalanced 1/4" phone jacks.
Note: Guitars with active pickups can be connected 
directly to any of the inputs. Guitars with passive 
pickups (i.e., guitars that do not have an internal 
each key or pad. Alternatively, these samples could be 
assigned at one‐octave intervals, and played as phrase 
variations with different playback pitches.
The OASYS can hold a maximum of 1,000 
multisamples in its internal memory.
A multisample can be selected as the oscillator and 
wave sequence for a program, and played as a 
program. In a combination, they can be combined with 
preset programs, and used in a multi. They can be used 
with the KARMA function to produce interesting 
results (for example, by using the KARMA function to 
automatically play sound effects or spoken samples).
Multisample
Index001
Index002
Top Key
Top Key
Index 001
Index 002
0000:
0001:
Sample A
Sample B
Multisample
Wave Seq.
Sample
Drum Kit
preamp) can be used with inputs 1 and 2, but the 
impedance mismatch will cause both a change in tone 
and a reduction in volume. For best results, route such 
guitars through a pre‐amp or effects unit before 
connecting them.
S/P DIF L, S/P DIF R: These are the input settings for 
digital input from an instrument or DAT player etc. 
connected to the S/P DIF IN jack. The S/P DIF input 
and output of the OASYS support 48 kHz and 96 kHz 
sample rates. Make this selection in "S/P DIF Sample 
Rate." 96 kHz sample rate data is converted to 48 kHz 
when it is sampled.
When using S/P DIF, make sure that the System 
Clock is set correctly. For more information, see 
"System Clock" on page 702 of the Parameter 
Guide.
Bus Select (IFX/Indiv.)
This specifies the bus for the external audio input 
signal.
L/R: The external audio input signal will be sent to the 
L/R bus. Choose this if you want to sample the 
performance of the OASYS itself along with the other 
signals of the L/R bus. Set Source Bus to L/R. Normally 
you will use this when you sample in Sampling mode.
IFX1...12: The external audio input signal will be sent 
to the IFX1–12 bus. Choose one of these settings if you 
want to apply an insert effect while recording. Set the 
Source Bus to match the Bus Select that follows the 
insert effect.
Preparations for sampling
Index003
Index004
Top Key
Top Key
Index 003
Index 004
0002:
0003:
Sample C
Sample D
Program OSC (Single/Double)
Program OSC (Single/Double)
Program OSC (Drums)
125