Korg Oasys Operation Manual page 156

Open architecture synthesis studio
Hide thumbs Also See for Oasys:
Table of Contents

Advertisement

Sampling (Open Sampling System)
4. We will be modifying the Audio Input settings, so 
turn the Input "Use Global Setting" off.
5. Choose the Auto HDR/Sampling Setup page menu 
command.
The dialog box will appear.
6. Choose "In‐Track Sampling."
7. Make the following settings for "In‐Track 
Sampling."
Source Audio: Audio Input 1/2
The input from the AUDIO INPUT 1 and 2 jacks 
will be sampled.
Mono–L/Mono–R/Stereo: Stereo
The sound will be sampled in stereo.
To: as desired
The track you want to use for In‐Track Sampling. 
MIDI note data to trigger the sample will be 
recorded in the track you selected.
Program: as desired
The convert‐destination program number. When 
sampling is completed, a new multisample will be 
automatically created, converted to a program, and 
assigned as the program for the track.
8. Press the OK button to execute the command.
Preparations for In‐Track Sampling are now 
completed.
Let's take a look at the settings that were made.
– Audio Input –
INPUT1
Bus Select (IFX/Indiv.): Off
Pan: L000
Level: 127
REC Bus: 1/2
The input from AUDIO INPUT 1 will be sent to REC 
bus.
– RECORDING LEVEL–
Recording Level: 0.0
This is the default setting for sampling.
– Sampling Setup –
148
Source Bus: REC 1/2
The sound sent to REC 1/2 bus will be sampled.
Trigger: Sampling START SW
Press the SAMPLING REC switch to enter record‐
standby mode. Then press the SAMPLING 
START/STOP switch to start sampling.
Save to: RAM
The sample will be recorded to RAM memory.
Mode: L‐Mono
The sound of the internal left channel will be 
sampled in mono.
9. For this example, change the settings as follows.
Pan: C64
"Trigger": Threshold, "Threshold Level": as desired
"Sample Time": as desired
10.Play your guitar at the volume that you will be 
recording.
If the display indicates "ADC OVERLOAD !" (AD 
converter input overload), turn the rear panel 
[LEVEL] knob toward MIN to adjust the level 
appropriately.
For the best sound, adjust the level as high as 
possible without allowing the "ADC OVERLOAD !" 
indication to appear.
11.Press the SAMPLING REC switch.
When you play your guitar, the level meter will 
indicate the volume at which the guitar will be 
sampled.
If the display indicates "CLIP!," use the VALUE 
controllers to lower the Recording Level slider (in 
the right of the display) below +0.0 to an 
appropriate level.
12.When you have finished making adjustments, 
press the SAMPLING REC switch.
13.Press the SAMPLING REC switch, and then the 
SAMPLING START/STOP switch to enter 
recording‐standby mode.
Press the LOCATE switch to reset the song playback 
location to the beginning of the song, and press the 
SEQUENCER START/STOP switch to play back.
Begin playing at the point where you want to 
record.
Sampling will begin when the Threshold Level 
volume is exceeded.
14.At the point where you want to stop sampling, 
press the SEQUENCER START/STOP switch.
Song playback and sampling will end.
Sampling will also stop if the specified Sample 
Time is reached.
15.Press the LOCATE switch to return to the 
beginning of the song, and press the SEQUENCER 
START/STOP switch. Notice that the sampled 
audio is played back along with the song.
For details on how the Compare function works for 
In‐Track Sampling, refer to "In‐Track Sampling" on 
page 147.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents