3
5
6
7
Ed. 05-2011
GENERAL PROCEDURES
-
Remove clamp (3) and disconnect secondary air circuit pipe (4) from exhaust
manifold (5).
4
H02725
-
Release the two springs (6).
H02726
-
To remove manifold (5), loosen screw (7) with an 8 mm wrench.
H02727
8
5
H02728
Check seal (8) and metal gasket (9) for wear. Change, if damaged.
E.11
9