Format Assign
Format Extract by ESP
You can extract and insert several character sequences
using ESP's Symbol Parse feature. In this example, the
selected extraction range is characters 2-4. The "Sample
Symbol Parse" example on the Symbol Parse dialog
shows the selected character positions extracted and
output as desired. Simultaneously, the data string from
the actual selected symbol is displayed at the bottom left
of the Parse Table, followed by the user-defined
extracted output ("icr" in this example).
14-6
The Extract Range
function corresponds to
the Start Location and
Length parameters in
the Format Extract
serial command.
Quadrus EZ Reader User's Manual
Need help?
Do you have a question about the Quadrus EZ Reader and is the answer not in the manual?
Questions and answers