Green Flash Duration - Microscan Quadrus EZ Reader User Manual

Barcode scanners
Table of Contents

Advertisement

Green Flash Duration

Usage:
A visual verification that a good read has occurred.
When a good read occurs, the Green flash LED's will illuminate and stay on
Definition:
for the time set for the Green Flash Duration value.
Serial Cmd:
<K750,green flash mode,x-pattern
Default:
100
(1 second)
Options:
0 to 65535 (in 10mS increments)
Note: Green Flash Duration values only take effect in Static Presentation Mode.
Beeper
Usage:
An audible verification that either a good read or a noread has occurred.
Definition:
A beep is emitted either after each good read or noread.
Serial Cmd:
<K702,beeper
Default:
Good Read
0 = Disabled
Options:
1 = Good Read
2 = Noread
Note: Beeper will also sound if any of the following occur:
• the reader is defaulted
• a send/save command from ESP or an Exit command from any embedded menu
• at the conclusion of a calibrate procedure
• a <Z>, <Zp>, <Zd>, or
Quadrus EZ Reader User's Manual
status>
<K701,1>
command is sent
I/O Parameters
status,green flash
duration>
5-21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Quadrus EZ Reader and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Quadrus ez

Table of Contents