Global
Global
Total Read Time and Symbol Quality Separator apply to all three Symbol Quality
groups: ISO/IEC 15415, Grading, and Inkjet/Direct.
Total Read Time
The time that transpires between the image capture and the output of the
decoded data, including locate time.
Definition:
If enabled, is appended to the symbol.
Serial Cmd:
<K710,[not changed in this
Default:
Disabled
Options:
0 = Disabled
Symbol Quality Separator
Definition:
Inserts a separator between each enabled field of the symbol quality output.
Serial Cmd:
<K708,symbol quality
Default:
<SP>
(space character)
Options:
Any ASCII character except a
6-4
context],total read
1 = Enabled
separator,output mode>
NULL < ,
or >.
time>
Quadrus EZ Reader User's Manual