Minimum Number of Qualified Scan Lines
Sets the minimum number of scans that have the required number of bars
Definition:
set in Minimum Number of Bars.
<K717,minimum number of
Serial Cmd:
scans,start and stop status>
Default:
0
Options:
0 to 11 (0 is disabled)
Start/Stop Status
When enabled, both Start and Stop characters need to be present to qual-
ify as a decodable symbol. In the case of PDF417, only a Stop or Stop
needs to be present.
Definition:
Note: This parameter does not apply to UPC, Pharmacode, RSS and Micro
PDF417.
<K717,minimum number of bars,minimum number of qualified
Serial Cmd:
and stop
Default:
Disabled
Options:
0 = Disabled
Quadrus EZ Reader User's Manual
bars,minimum number of qualified
status>
1 = Enabled
I/O Parameters
scans,start
5-11
Need help?
Do you have a question about the Quadrus EZ Reader and is the answer not in the manual?
Questions and answers