Options 3; Dd 243:2002 Options - Texecom Premier 24 Installation Manual

Texecom premier 24 installation manual
Hide thumbs Also See for Premier 24:
Table of Contents

Advertisement

The Programming Menu

Options 3

F – Faults Eng Reset (Default = Disabled)
The system can be programmed for Engineer or User reset
following any Fault with exception to "No ATS Available"
and "AC Fail". If programmed as 'Faults Eng Reset' the
system will respond as follows:
All System Faults (except No ATS Available and AC Fail)
can only be reset using an Engineer code or "Anti-code
Reset" (if enabled).
A – No ATS Eng Reset (Default = Disabled)
The system can be programmed for Engineer or User reset
following a "No ATS Available" fault (ATS = Alarm
Transmission System). If programmed as "No ATS Eng
Reset" the system will respond as follows:
The No ATS Available fault can only be reset using an
Engineer code or "Anti-code Reset" (if enabled).
A – AC Fail Eng Reset (Default = Disabled)
The system can be programmed for Engineer or User reset
following an AC Mains Fail. If programmed as 'AC Fail Eng
Reset' the system will respond as follows:
The AC Mains Fail fault can only be reset using an
Engineer code or "Anti-code Reset" (if enabled).
M – Mask When Armed (Default = Disabled)
When 'Mask When Armed' is enabled the zone will register
a masking fault if the system is armed and a masking fault
occurs.
When disabled, the zone will never register a Masking fault
when the system is armed and a Masking Fault occurs.
!
The way the system responds to a Masking fault is
determined by System Config option 26 (see page
46).
F – FOB After Entry (Default = Disabled)
When 'FOB After Entry' is enabled the system can only be
disarmed with a Radio FOB once the Entry procedure has
been started.
When disabled, the system can be disarmed with a Radio
FOB at any time.
42

DD 243:2002 Options

To comply with DD 243:2002, during the normal entry
delay, the control panel must prevent a Confirmed Intruder
Alarm from being reported to the Alarm Receiving Centre.
If a Portable ACE i.e. Electronic Keyswitch, Key Fob, Tag,
Swipe Card etc is being used for disarming, it is permissible
for the Confirmed Intruder Alarm signal to be re-enabled after
the entry delay has expired.
The previous two options have been provided to ensure
that the control panel can be programmed to comply with
this standard if required.
WARNING
Owing to the ability to disable ALL of the confirmation
facilities, the customer should be advised in writing by
the alarm company that ALL means of alarm
confirmation are disabled when the initial entry door is
opened. The alarm company should then obtain written
acceptance from the customer of the disabling of the
means of alarm confirmation.