Premier 24 Installation Manual

Plug-on Digimodems

The
Com300
is
a
multi
communicator/300-baud modem for use with a standard
analogue telephone line.
The
Com2400
is
a
communicator/2400-baud modem for use with a standard
analogue telephone line in addition, this modem can also
send Short Message Service (SMS) text messages to a
mobile phone.
The
ComISDN
is
a
communicator/modem for use with an ISDN telephone line.
These Digimodem can be used to report system events to an
Alarm Receiving Centre using Fast Format, Contact ID or SIA
Level II or to upload/download control panel information
using the Wintex UDL software and a PC.
Plugging on the Digimodem
Ensure that the board is the correct way up (see below).
Locate the eight-pin plug into the digimodem socket on the
control panel and line up the mounting holes with the pillars
in the base. Once all the holes line up, press down gently
until the pillars snap into the holes.
Panel Outpus
1
2
3
4
5
6
7
8 L\W R\R
Z4
Z5
Z6
Z7
Z8
Left side of Premier 24
INS248
format
8-channel
multi
format
8-channel
multi
format
8-channel
Standard Telephone Line Connections
A standard telephone line must be connected to the
digital
Com300 or Com2400 digimodem as shown below:
Master
digital
Socket
digital
Com300
or
Com2400
ISDN Telephone Line Connections
An ISDN telephone line must be connected to the ComISDN
digimodem as shown below:
!
For details on testing the digimodems, see page 60.
6
5
4
T = 5 or A - White/Blue ring
3
R = 2 or B - Blue/White ring
2
1
Telephone cable
Type 1/0.5mm CW1308
This terminal must be connected to
the incoming AC Mains earth supply
T
R
T1
To other telephone
extension sockets
R1
ISDN
Terminal
RJ45
Lead
ComISDN
Installation
25