Texecom Premier 24 Installation Manual page 45

Texecom premier 24 installation manual
Hide thumbs Also See for Premier 24:
Table of Contents

Advertisement

Premier 24 Installation Manual
10 - View Zone Faults
Active zones and their status are always displayed in real
time on the keypad when the system is disarmed.
Hide Zone Faults (Default)
Active zones and their status are never displayed in real
time on the keypad when the system is disarmed.
11 - Enable Code Tampers (Default)
24 invalid key presses on a keypad will cause a Code Tamper
condition (see option 17).
No Code Tampers
A Code Tamper condition will never occur when the keys on
a keypad are pressed more than 24 times.
12 - Code Tamper Alarm (Default)
A Code Tamper condition will cause a Tamper alarm.
Code Tamper Lockout
A Code Tamper condition will cause the keypad to lockout
for 5 minutes.
13 - Short = Active
The control panel will see a zone that is in the short circuit
condition as 'Active'.
Short = Tamper (Default)
The control panel will see a zone that is in the short circuit
condition as a 'Tamper'.
14 - R/R=Reset Only (Default)
When 0V is applied to the control panel R/R input, any
outstanding alarms will be reset (see page 41 for details).
R/R=Silence/RST
When 0V is applied to the control panel R/R input the
internal sounders will be silenced. When 0V is applied to the
R/R input a second time, any outstanding alarms will be
reset. (this would normally be used when Audio Verification
is required).
15 - Timed Test Call (Default)
A test call to the Alarm Receiving Centre will occur every
time the 'Test Call Every' timer expires.
Test Call = CT3
A test call to the Alarm Receiving Centre will occur every
time 'Control Timer 3' activates.
16 - Batt Test Timed (Default)
A battery test will occur every time the 'Batt Test Period'
timer expires.
Batt Test = Disarm
A battery test will occur every time the system is disarmed
or after the 'Batt Test Period' timer has expired (whichever
occurs first).
17 - Bell = 1st Alarm (Default)
The 'Bell' and 'Strobe' outputs will activate after an Intruder
alarm (1st Alarm) occurs.
Bell = 2nd Alarm
The 'Bell' and 'Strobe' outputs will activate after a Confirmed
alarm (2nd Alarm) occurs.
INS248
18 - SNDR = 1st Alarm (Default)
The internal sounders will sound after an Intruder alarm (1st
Alarm) occurs.
SNDR = 2nd Alarm
The internal sounders will sound after a Confirmed alarm
(2nd Alarm) occurs.
19 - Abort=Eng.Reset (Default)
An Intruder alarm that is aborted can only be reset by an
Engineer/Anti-code.
Abort=User Reset
An Intruder alarm that is aborted can be reset by the User.
20 - 8XE = Zones 9-16 (Default)
The 8 zones on the 8XE local zone expander will report as
zones 9 to 16.
8XE = Tampers 1-8
The 8 zones on the 8XE local zone expander will report as
the tampers for zones 1 to 8.
21 - 2nd Zone = Confirm (Default)
After the entry timer has expired, activation of 2 more zones is
required to generate a Confirmed alarm
1st Zone = Confirm
After the entry timer has expired, activation of 1 more zone is
required to generate a Confirmed alarm
22 - Access No Conf. (Default)
Zones programmed as 'Guard Access' can never generate
a confirmed alarm once the entry timer has started.
Access = Confirm
Zones programmed as 'Guard Access' can generate a
confirmed alarm once the entry timer has expired.
23 - EN50131 Disabled (Default)
The Control Panels EN50131 options are disabled.
EN50131 Enabled
The Control Panels EN50131 options are enabled.
!
This options must be enabled to comply with EN50131
24 - Panel Grade 2
All options relating to PD6662: 2004/EN 50131-1 Grade 3
that are not required for Grade 2 systems are disabled
automatically. Also, the Premier Anti-code reset becomes
the standard 4 digit number and all user and engineer
codes can be 4, 5 or 6 digits.
Panel Grade 3
All options relating to PD6662: 2004/EN 50131-1 Grade 3
systems are enabled automatically. Also, the Premier Anti-
code reset becomes a 6 digit number and all user codes
can only be programmed as 5 or 6 digits.
25 - Disable RF PA(Default)
When a 'RadioPlus' Transmitter FOB is being used with the
alarm system, the Panic Alarm (PA) function i.e. Pressing
buttons 1 and 2 together, is disabled.
Enable RF PA
When a 'RadioPlus' Transmitter FOB is being used with the
alarm system, the Panic Alarm (PA) function i.e. Pressing
buttons 1 and 2 together, is enabled.
Programming the Control Panel
45