The Programming Menu
Log Event
# RESET -
Engineer Reset
Anti-Code Reset
Remote Reset
Key switch Reset
User Reset
EXP # Reset
Remote PC Reset
FUSE # FAIL
AC POWER
LOW BAT
POWERED UP
BELL FUSE
LINE FLT
Panel Line Fault
Com??? Line Fault
COMS FAILED
DOWNLOAD START
DOWNLOAD END
LOG ALERT
DATE CHANGED
TIME CHANGED
PROG. START
PROG. END
BOX LID
BELL # Tamper
AUX # Tamper
EXP # Tamper
RKP # Tamper
RKP # LOST
EXP # LOST
FIRE ## Active
Zone ## Tamper
Zone ## Active
Zone ## Restore
Zone ## Omitted
Zone ## Un-Omit
Zone ## Test Start
Zone ## Test End
RKP LOCKED #
CODE # Tamper
TEST FAIL ##)
MANUAL TEST CALL
AUTO TEST CALL
WALK
TESTED ##
DEFAULTS LOADED
FIRST KNOCK ##
CURRUPT EVENT
78
The system has been reset using keypad # following an Intruder alarm
A reset has been performed using an Engineers code
A reset has been performed using the Anti-code reset procedure
A reset has been performed using the 'Remote Reset' input
A reset has been performed using a key switch
A reset has been performed using a User code
A reset has been performed using the input on expander # (programmed as reset)
A reset has been performed by the remote download PC
The Auxiliary 12V Fuse/PTC in device # has failed
The control panel has registered a AC Mains failure
The control panel has registered a low battery condition
System Power Up (without doing a factory restart)
The control panel Bell Fuse has failed
There is a problem with the telephone line
The control panel line fault input has been activated
The Com300, 2400 or ISDN has detected a line fault
The Com300 or Com2400 has failed to report to the Alarm Receiving Centre
An Upload/Download has been initiated
The Upload/Download has finished
80% of the Event Log has filled (since the last Upload/Download)
The control panel Time has been changed
The control panel Date has been changed
An Engineer code has been entered
The Engineer has logged out of the Programming menu
The control panel lid has been removed causing a Tamper alarm
A Bell Tamper input from device # has been activated
An Auxiliary Tamper input from device # has been activated
The cover of expander # has been removed
The cover of keypad # has been removed
Keypad ## has been lost from the network
Expander ## has been lost from the network
Zone ## (programmed as Fire Alarm) has caused an alarm
Zone ## has caused a Tamper alarm
Zone ## has been activated
Zone ## has restored to its normal condition
Zone ## has been omitted
Zone ## has been reinstated
Zone ## has been put on test
Zone ## has been removed from test
Keypad # has been locked out from too many invalid key presses
Too many invalid key presses have caused a tamper alarm from keypad #
Zone ## has failed its Soak test
A Manual test call has been initiated
An Automatic test call has been initiated
The Walk Test mode has been initiated
Zone ## has been tested
The factory default values have been loaded into memory
Zone ## (which is programmed as double knock) has activated for the first time
No event has been stored in memory
Premier 24 Installation Manual
Description
INS248