Area Options - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Programming the Control Panel

Area Options

Yes
5
jkl
Yes
No
4
ghi
Yes
These options control how various features affect each area.
Any number of areas can be assigned to each option.
1 - Auto Part Arm
Areas assigned to 'Auto Part Arm' will fully arm if an
'Entry/Exit' zone is activated during the exit mode and will
'Part Arm 1' if an 'Entry/Exit' zone is not activated during the
exit mode.
Areas not assigned to 'Auto Part' will always fully arm.
2 - Part Arm Instant
Areas assigned to 'Part Arm Instant' will arm instantly when
part arming.
Areas not assigned to 'Part Arm Instant' will use the area exit
timer when part arming.
3 - Part Arm Silent
Areas assigned to 'Part Arm Silent' will never generate Exit
tones when part arming.
Areas not assigned to 'Part Arm Silent' will always generate
Exit tones when part arming.
4 - Remote Arm
Areas assigned to 'Remote Arm' can be armed remotely
using the Wintex UDL software and a PC.
Areas not assigned cannot be armed remotely.
5 - Remote Disarm
Areas assigned to 'Remote Disarm' can be disarmed
remotely using the Wintex UDL software and a PC.
Areas not assigned to 'Remote Arming' cannot be disarmed
remotely.
6 - Panel Tamper
Areas assigned to 'Panel Tamper' will cause a Tamper alarm
when the control panel cover is removed.
Areas not assigned to 'Panel Tamper' will never cause a
Tamper alarm when the control panel cover is removed.
42
Use the SCROLL
key to select an
area option
Press NO to change
the area option
Use keys 1 - 8
to select an area
e.g. 4 = D
Premier 48, 88, 168 & 640 Installation Manual
7 - Bell Tamper
Areas assigned to 'Bell Tamper' will cause a Tamper alarm
when the Bell tamper loop is broken.
Areas not assigned to 'Bell Tamper' will never cause a
Tamper alarm when the bell tamper loop is broken.
8 - Auxiliary Tamper
Areas assigned to 'Auxiliary Tamper' will cause a Tamper
alarm when the Auxiliary tamper loop is broken.
Areas not assigned to 'Auxiliary Tamper' will never cause a
Tamper alarm when the auxiliary tamper loop is broken.
9 - Panel Speaker
Areas assigned to 'Panel Speaker' will cause the control
panel speaker to activate when those areas are in alarm,
entry and exit etc.
Areas not assigned to 'Panel Speaker' will never cause the
control panel speaker to activate when those areas are in
alarm, entry and exit etc.
10 - Bell & Strobe op
Areas assigned to 'Bell & Strobe op' will cause the
'Bell/Strobe' output on the control panel to activate when an
alarm occurs in those areas.
Areas not assigned to 'Bell & Strobe op' will never cause the
'Bell/Strobe' output on the control panel to activate when an
alarm occurs in those areas.
11 - Alarms Eng Reset
Each area can be programmed for Engineer or User reset
following an Intruder alarm. Areas Assigned to 'Alarms Eng
Reset' will respond as follows:
The assigned areas can only be reset using an Engineer
code
If 'Anti-code Reset' is enabled (option 14) the assigned
areas can also be reset using the Anti-code
Areas not assigned to 'Alarms Eng Reset' can be reset with
any User code that is valid for those areas.
12 - Confirmed Reset
Each area can be programmed for Engineer or User reset
following a Confirmed alarm. Areas Assigned to 'Confirmed
Reset' will respond as follows:
The assigned areas can only be reset using an Engineer
code
If 'Anti-code Reset' is enabled (option 14) the assigned
areas can also be reset using the Anti-code
Areas not assigned to 'Confirmed Reset' can only be reset
with any User code that is valid for those areas providing that
'Alarms Eng Reset' (option 14) is also programmed for user
reset.
13 - Tamper Eng Reset
Each area can be programmed for Engineer or User reset
following a Tamper alarm (when the area is unarmed). Areas
assigned to 'Tamper Eng Reset' will respond as follows:
The assigned areas can only be reset using an Engineer
code
If 'Anti-code Reset' is enabled (option 14) the assigned
areas can also be reset using the Anti-code
Areas not assigned to 'Tamper Eng Reset' can be reset with
any User code that is valid for those areas.
INS176

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier 168Premier 88Premier 640

Table of Contents