8XE Zone Expander

The Premier 8XE Zone Expander has:
8 fully programmable zones
Aux 12V Output
Expander Layout
Zones 9-16 or
Tampers 1-8
Connecting Expanders
The 8XE local zone expander plugs directly on to the
terminals located on the right hand side of the control panel
(see below for details). To install the local zone expander
proceed as follows:
1.
Ensure that all power is removed from the control panel
(mains and battery) before attempting to fit the expander.
2.
Push the four support pillars (supplied) into the four
locating holes on the control panel PCB.
3.
Align the local expander connector with the 8 way plug
(JP6) on the control panel. Push expander into place,
ensuring that all four pillars clip into the four locating
holes on the local expander.
Zone Numbering
The table below shows the zone allocation when the
expanders are installed:
Configuration
Panel Zones
8XE = Zones
8XE= Tampers
Expander Zones
The expander has eight programmable zones (see page 21
for wiring details). Each zone is also fully programmable
(see page 34 for programming details).
INS248
Connector for
plugging on JP6
control panel
Aux 12V
(1 Amp)
Expander Zones
1 to 8
9 to 16
1 to 8
Tampers 1 to 8
Installation