Zone Attributes 1

Attributes can be assigned to a zone to alter its operation i.e.
a Guard zone with the 'Access' attribute will allow the user to
walk past the detector without causing a 'Fault' during the
exit mode or an Intruder alarm during the entry mode.
Select attributes by pressing keys 1 to 8 (a letter on the
display means the attribute is selected, a star on the
display means the attribute is not selected).
The following attributes are available:
O - Omittable
Zones with this attribute can be manually omitted.
Zones without this attribute cannot be manually omitted.
F - Force Omit
Zones with this attribute will be omitted if they are not
secure at the end of the exit mode.
Zones without this attribute will cause an 'Arm Fail' if they
are not secure at the end of the exit mode.
1 - Part 1 Omit
Zones with this attribute will be omitted when 'Part Arm 1'
is selected. Keyswitch zones with this attribute will perform
a 'Part Arm 1'.
Zones without this attribute will not be omitted when 'Part
Arm 1' is selected.
2 - Part 2 Omit
Zones with this attribute will be omitted when 'Part Arm 2'
is selected. Keyswitch zones with this attribute will perform
a 'Part Arm 2'.
Zones without this attribute will not be omitted when 'Part
Arm 2' is selected.
3 - Part 3 Omit
Zones with this attribute will be omitted when 'Part Arm 3'
is selected. Keyswitch zones with this attribute will perform
a 'Part Arm 3'.
Zones without this attribute will not be omitted when 'Part
Arm 3' is selected.
1 - Chime 1
Zones with this attribute will cause the internal sounders to
generate a single Chime tone when activated.
2 - Chime 2
Zones with this attribute will cause the internal sounders to
generate a double Chime tone when activated.
G - Guard
Entry/Exit 1 or 2 or Guard Access Zones with this attribute
will cause an Intruder alarm when the system is part
armed.
Guard Zones with this attribute will become Entry/Exit 2
when the system is part armed.
Zones without this attribute will respond as normal.
36

Zone Attributes 2

Select attributes by pressing keys 1 to 8 (a letter on the
display means the attribute is selected, a star on the
display means the attribute is not selected).
The following attributes are available:
D - Double Knock
Zones with this attribute will only cause an alarm if it is
activated twice within the 'Double Knock' time window or
for the duration of the time window.
Zones without this attribute will respond as normal.
S - Shunt Group
Zones with this attribute will be isolated whenever a 'Shunt'
code is entered or a 'Shunt' keyswitch is operated and will
be reinstated when the code or keyswitch is used again.
Zones without this attribute will respond as normal.
T - On Soak Test
Zones with this attribute will not cause an alarm if activated
during the 'Soak Test Time' (see page 43 for details).
However, the system will record the event in the log and
indicate to the user that the zone has failed the test. A test
failure will NOT prevent the user from arming and will clear
when an Engineer code is entered.
Zones without this attribute will respond as normal.
A - Activity
Zones with this attribute will cause an activity fault to be
displayed at the time of arming if they have not been
activated during the 'Activity Delay' period. If 'Config.
option 14' (see page 44 for details) has been set to
'Activity Fault Bar' the system cannot be armed until the
zone has been activated (forced walk test).
Zones without this attribute will respond as normal.
R - Reset
Zones with this attribute will not be monitored during the
'Detector Reset' period i.e. when the exit mode is started
and power is removed from certain detectors (to reset
them) the 'Fault' on the zone is ignored.
Zones without this attribute will be monitored as normal.
I - Inverted
Zones with this attribute will report their 'Secure' and
'Active' status the opposite way round. 'Tampers' always
respond as normal.
Zones without this attribute will respond as normal.
Q - Quick Resp.
The response time of zones with this attribute is governed
by the 'Zone Loop' response Timer (see page 43 for details).
The response time of the zone is fixed at 250mS.
! - Shock
Zones with this attribute will cause any 'Entry/Exit 1' zone type
to automatically become a 'Guard' zone for 10 seconds.
Zones without this attribute will respond as normal.