  • Page 2 Contact 7 Contact 8 The Speech Dialler provides a means of communicating alarm information from an alarm control panel to a standard or mobile telephone. The unit is normally connected to an alarm control panel, which provides the necessary power and battery backup.
  • Page 3 Speech Dialler Installation Manual Inputs: The dialler has four trigger inputs; each input can be assigned a voice message and/or a text message (Speech & Text only). The trigger inputs are normally connected to the alarm control panel communicator outputs or bell output. Other devices such as smoke detectors or temperature sensors can be directly connected to the trigger inputs.
  • Page 4 Context Sensitive Help: When programming or operating the dialler you can press the help key and the unit will scroll the relevant information on the display. Speech Dialler Models: Two versions of the Speech Dialler are available: • Speech & Text: This model supports both speech and text messages.
  • Page 5 Speech Dialler Installation Manual 2. Installation General The unit requires a 12V @100mA DC power source, which is normally supplied by the auxiliary power output of an intruder alarm control panel. If the unit is not connected to an alarm control panel then a suitable power supply will be required.
  • Page 6: Pcb Layout

    Speech Dialler Installation Manual PCB Layout 4 0V 12V Trigger Inputs Tamp OP1- OP2- Telephone connections (TNV) Tamper switch & Programmable outputs, tamper and remote microphone connections (SELV) Microphone Trigger Inputs and power supply connections (SELV) Loudspeaker connector (SELV) Connection terminals on the dialler are described as either “Safety Extra Low Voltage”...
  • Page 7 Tamp: These terminals provide tamper protection for the dialler and should be connected to the auxiliary tamper circuit on the alarm control panel. OP1 & OP2: Two programmable switched –ve @100mA outputs. Mic: A Texecom Remote Microphone Module can be connected to this input, to enhance the listen-in mode. INS232-2...
  • Page 8 Speech Dialler Installation Manual Control Panel Connection Table The table below shows connection details for various alarm control panels: Trigger Inputs Trigger Control Panel +12V Polarity Fire Intruder A1 Advantage Bell - Aux + Aux - ADE Accenta 6 13V +...
  • Page 9 Connect to Earth #" Failure to fit an earth cable may prevent proper operation of the system and will invalidate the Texecom warranty and product approval. The telephone cable must be secured using the screw mount cable tie provided. INS232-2...
  • Page 10: Specifications

    After the unit has finished initializing/loading defaults the display will show “,,,,1&.$2"#1,,,,”. The unit will beep once if it is a Speech Dialler and twice if it is a Speech & Text Dialler. To select the programming mode enter the $%&'...
  • Page 11 As the dialler is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the dialler failed to function correctly.