The Programming Menu
The system has the following download options:
PC No. 1
This is the telephone number that is dialled by the modem
when 'Call-back Number 1' is requested by the remote
UDL computer.
When
entering
telephone
repeatedly will allow the following characters to be selected:
,
(3 second pause)W(10 second pause)+R(recall signal).
!#
PC No. 2
This is the telephone number that is dialled by the modem
when 'Call-back Number 2' is requested by the remote
UDL computer.
UDL ID:
When the remote downloading computer dials into the
system, the control panel compares the UDL password sent
by the computer with UDL password stored in the control
panel. If the passwords match, access to the control panel is
granted, if they don't match, access is denied.
!
If more than three attempts at reporting are made
with a wrong password, the modem will lock out for
4 hours or until a User code is entered.
The UDL password programmed in this option must
also be programmed in the customer account on
the remote downloading computer. This password
can be up to 16 characters (numbers and letters).
If no UDL Password has been programmed, access
to the control panel can be gained by using the
engineers code as the UDL Password.
UDL Options
There are 6 UDL options that affect how and when access
to the control panel via the Wintex UDL software is allowed.
Select options by pressing keys 1 to 6 (a letter on the
display means the option is selected, a star on the display
means the option is not selected).
The following UDL options are available:
A - DL Attended (Default = OFF)
The system will not allow the remote downloading
computer access without for user authorisation first.
M - Man Call-Back (Default = ON)
The system will not use the automatic call back feature.
The user must instruct the panel to call back the remote
downloading computer.
The Auto Call-Back feature operates as follows:
The remote downloading computer calls the
control panel and establishes a connection
The UDL password is verified and the remote
downloading computer instructs the panel to call it
back using one of the 3 call back numbers
The panel hangs up and dials the requested
number and re-establishes the connection with the
remote downloading computer
66
numbers,
pressing
5
D - Call Defeat (Default = ON)
The modem will answer incoming calls as follows:
The modem must detect one or more rings and
the number of rings must NOT exceed the value
set up in 'Rings Required'
When the ringing stops, the panel will start a 30
second delay timer
If the modem detects ringing before the timer
expires it will answer the call immediately
L - Armed DL Limited (Default = OFF)
The panel will not allow download access when the system
is armed (also see below).
A - Only Full Armed (Default = OFF)
The panel will not allow download access when the system
is fully armed.
K - Online RKP=Off (Default = OFF)
The control panel cannot be accessed using the 'On-line'
keypad feature of the Wintex UDL software.
Rings Required
This counter controls the number of rings the modem
needs to see before it will answer the call (Default = 005).
UDL Dial Attempt
If a 'Call-Back' is started, this option controls how many
times the modem will try to call the remote downloading
computer before giving up (Default = 003).
!
Enter the number of dialling attempts. This number is
limited to 9. If this value is set to 0, the Digimodem will
never dial out.
This only affects the modem for download access
and does not affect the operation of the Digimodem
in any way.