Expander Auxiliary Input

Each expander has an input that can be programmed for
one of the following options. If not being used, the input
must be programmed as 'Not Used' (Default = Not Used).
Not Used (Default)
Never monitored by the system.
Aux Tamper
Normally used for monitoring the box tamper of auxiliary
devices such as power supplies etc (remove 0V for
Tamper alarm).
Bell Tamper
Normally used for monitoring Bell Tamper returns (remove
0V for Tamper alarm).
Silence Sounders
Normally used to silence the Internal sounders following
an Intruder alarm and would be used in conjunction with
Audio Verification units (apply 0V to silence).
PSU Fault
Normally used for monitoring an external power supply for
faults i.e. mains power off etc (remove 0V for mains fault).
Shunt Key
Normally wired to a key switch. When the input is 'Active'
(0V applied), any zone with the 'Shunt' attribute will be
isolated until the input returns to 'Secure' (0V removed).

Expander Speaker Volume

This option controls the volume level of advisory tones
from loudspeakers connected to the expanders. Advisory
tones consist of 'Entry/Exit' and 'Warning' type tones.
1 = minimum; 8 = maximum (Default = 5).
!
Alarm tones are always full volume.
INS248
Programming the Control Panel

Expander Sounder Options

The speaker output on the expander can be programmed
so that certain types of tones are not generated. When
deselected, Fire, Alarms, Fault, Service, Entry, Exit and
Chime tones will not be heard.
Select tones by pressing keys 1 to 8 (a letter on the display
means the tone is selected, a star on the display means
the tone is not selected).
F - Fire Tones On (Default = ON)
Fire alarm tones will be generated by the expander
sounder/speaker.
A - Alarm Tones On (Default = ON)
Intruder alarm, Tamper alarm and PA alarm tones will be
generated by the expander sounder/speaker.
F - Fault Tones On (Default = ON)
Fault
tones
will
be
sounder/speaker.
S - Service Tone On (Default = ON)
Service and Warning tones will be generated by the
expander sounder/speaker.
E - Entry Tones On (Default = ON)
Entry
tones
will
be
sounder/speaker.
X - Exit Tones On (Default = ON)
Exit
tones
will
be
generated
sounder/speaker.
C - Chime Tones On (Default = ON)
Chime 1, 2 and 3 tones will be generated by the expander
sounder/speaker.