7) Installation Instructions (Mortise)
7.5) Installation of Cylinder and Outside Keypad Escutcheon
Cylinder Installation
Note: For devices without cylinders, skip this section.
1. Back cylinder set screw out of Mortise Lock.
2. Insert cylinder through trim assembly and thread into Mortise Lock until cylinder is flush with
escutcheon. Keyway should be vertical with plug toward lever.
3. Tighten cylinder set screw.
4. Assemble Mortise Lock armor front with (2) screws.
5. Tighten all screws for lock, trim assembly and exit device.
Outside Keypad Escutcheon
1. For exterior applications, it is recommended that the Trim Gasket (provided) be applied
as shown.
2a. For fire rated devices, feed keypad ribbon cable/connector and ground wire from outside of
door through fire stop plate and hole in door.
2b. For non fire rated exit devices, feed keypad ribbon cable/connector and ground wire through
hole in door.
3. Place escutcheon against door surface.
GASKET APPLICATION:
Peel off the adhesive protective paper from
gasket. Feed Keypad ribbon cable and ground
wire through gasket opening as shown and firmly
press gasket to escutcheon, aligning edge of
gasket with the edge of the escutcheon.
Keypad Ribbon Cable
Gasket
(optional)
Ground Wire
17
Outside
Of
Door
Fire Stop Plate
Cylinder Set Screw
Armor
Front