Advertisement
![]() |
Fingerprint Sensor |
![]() |
Keypad(10-key) |
![]() |
Dead Bolt Jam Lamp |
![]() |
Battery Change Lamp |
![]() |
Emergency Power Supply Terminal (Emergency Key) |
![]() |
Emergency Power Supply Terminal (9V Emergency alkaline battery) |
Optional
9V Emergency alkaline battery
Emergency Key
Parts | Specifications | Remarks | |
Front Body | 66(W) X 176(H) X 31.5(D), Zinc die-casting | Operating temperature -15~55˚C (5~131˚F) | |
Main Body | 70(W) X 170(H) X 35(D), ALDC | ||
User code | 100 different User codes | Up to 100 User code | |
Fingerprint | 100 different fingerprints | Up to 100 fingerprints | |
Emergency Key | 3EA | ||
Battery | 4EA 1.5V AA Alkaline batteries (Operating voltage: 4.5~6V) | It lasts a year if used 10 times a day. | |
Optional | Remote Controller | Wireless | Optional |
※ Battery life may vary depending on temperature, moisture levels, frequency of use and the quality of the batteries.
※ Please make sure that all parts are included when purchasing the product.
※ Optional products may not be available depending on your country or local dealer.
![]() |
![]() |
![]() |
Slot for Remote control module (Optional) |
![]() |
1.5V AA Alkaline Batteries (4PCS) |
![]() |
Thumb turn knob |
![]() |
Battery Cover |
![]() |
Open / Close button |
Normal Mode: Without a designated person, anyone who knows 'User PIN Code' has authority to set features.
Master Code: Only a designated person who knows 'Master PIN Code' has authority to set features.
Visitor Code: The visitor code is different from user code and given out to visitors only.
Onetime Code: The onetime code is used only once for unlocking the door lock and automatically deleted after usage.
User Slot Number: It should be 2 digits(like '01', '02'...'99', '00') and available in advanced mode.
![]() |
Touch the Keypad of the Front Body with your palm to begin |
![]() |
Press ![]() |
![]() |
Press ![]() |
![]() |
Press ![]() |
![]() |
Enter User Fingerprint (Up to 100EA) |
![]() |
Enter User Code (4 ~ 10 digits) |
![]() |
Enter Master Code (4 ~ 10 digits) |
![]() |
Enter Visitor Code (Only 4 digits) |
![]() |
Enter Onetime Code (Only 4 digits) |
![]() |
User Slot Number should be 2 digits (like '01'... '99' and '00': Location of 100th user slot must be assigned "00" instead of "100". ) |
![]() |
Rotation area to add more features |
Easy Scan by Goodix fingerprint solution: Live finger detection and secure matching The leading liveness performance improves the security of Yale smart lock dramatically.
This service is an innovative solution provided by YALE. Using high-tech IoT technology, user can access and unlock the digital door lock with your smartphone.
The automatic lock sensor detects the door closing and locks the door automatically within 5 seconds. The door locks when touch the keypad with the palm.
As the automatic lock function does not work in manual lock mode, make sure to check that the door is securely locked when leaving the premises.
After five (5) unsuccessful attempts of an invalid code or fingerprint, lock out mode is activated for 3 minutes.
When entering a pin code on the keypad, the user can open the door lock in silent mode.
Security enhancement to enter any number before or after entering a password to prevent the PIN code from being exposed.
It is a security-enhancing function that 'disables' authentication methods such as passwords, RFID cards and fingerprints from outside when setting up functions indoors.
It is a security-enhancing function that an alarm goes off if someone opens door from inside when setting up functions outside.
It guides user the operation status how to set each features, mode for easier and more convenient use.
Normal mode is a convenient mode for anyone to set the digital door lock. User can set password like user code, visitor code, onetime code and register user's fingerprints as well. Factory default is a normal mode.
How to press set button of remote controller
Press the set(registration) button located on the front of remote controller. You can press it using a pin like the picture.
Please note the following when using Yale Access Bluetooth App.
Touch the panel of fingerprint area sensor using registered fingerprint for 1 second
Fingerprint scan completed
Palm touch
Enter the Code
Palm touch
OR
Enter the button
Palm touch for 3 sec.
Enter the User PIN Code then touch the keypad with your Palm.
Press Open/Close button.
To open the lock, turn manual thumb turn knob from 'Close' direction to 'Open' direction.
Auto Lock status:
The built-in Auto Lock sensor automatically Locks a door within 5 seconds after the door was closed.
Manual Lock status:
Touch the keypad in the front body gently with your palm to lock a door.
Auto Lock status:
The built-in Auto Lock sensor automatically locks a door within 5 seconds after the door was closed.
Manual Lock status:
Turn manual thumb turn knob to close the lock, Into 'Close' marked direction.
※ Even after a door was locked by the Auto Lock function, please check again if the door was completely closed and locked.
Scan with registered fingerprint and hold the fingerprint area until you hear 3 beep sounds.
Palm touch
Enter the User PIN Code
Enter the button for 5 Sec.
When the door is unlocked from outside based upon proper authentication, the External forced lock will be released.
Press Open/Close button for 3 seconds until you hear "pik" beep.
Method 1: Press Open/Close button for 3 seconds until you hear "pik" beep.
Method 2: Turn manual thumb turn knob.
※ If you try to open a door with the manual thumb turn knob from inside when the Outside Forced Lock is set, the alarm goes off.
※ If the Inside Forced Lock is set, any attempt to open a door from outside whether it's be a Fingerprint or code won't work.
Intrusion Alarm: The alarm goes off when someone forces the door open. For example, In case of an intrusion by opening a gap in the door while the door is locked.
Broken Alarm: The alarm sounds when the front part is completely separated from the main set. For example, forced removal of external product (front body).
If an invalid user code, fingerprint is entered five(5) times in a row, lock out mode is activated and all buttons on the front body are not activated for three minutes.
There is no limitation for digits of Fake Pin Code.
Palm touch
Enter the User Code and Fake Code
OR
Enter the Fake Code and User Code
Palm touch
The product uses four 1.5V Alkaline AA batteries. They may sustain 1 year if used 10 times a day.(Users are advised to use authentic Alkaline batteries.)
You must replace all 4 batteries in the following cases:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE NATIONAL CODE OR RECYCLING PROGRAM.
Contact 9V battery
Palm touch
Enter the User Code and Palm touch
Duplicate if necessary
PIN Code Management (Up to 100 Users.) | ||
User Type | User Name | PIN Code |
Master | ||
User___ | ||
User___ | ||
User___ | ||
User___ |
Master mode is a mode in which only the administrator can set the door lock and provide access to other users. 100ea user passwords, 100ea fingerprint and individual registration and deletion of one-time passwords enable efficient management of visitors.
※ User Slot Number should be 2 digits.
like '01'... '99' and '00': Location of 100th user slot must be assigned "00" instead of "100".
※ Voice guidance function: The lock provides voice guidance for user and it will be helpful to set up lock's features correctly.
※ All registered passwords and other credentials can be deleted at the time of mode change.
※ Please install (register) the network module when you want to use a remote control or home network.
Do not install the digital door lock in an outdoor environment.
Do not attempt to disassemble the digital door lock by yourself.
Do not spray water directly or wipe with chemicals such as benzene, gasoline or alcohol.
Do not use force with a tool onto the product.
When using, remember that someone else can see the password.
Make sure to lock the door tight when you go out.
PLEASE READ INSTRUCTIONS BEFORE USE.
The functions and design of this product can be changed without prior notice for performance and quality improvement.
Packaging of this product can be recycled.
WEEE Note:
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check your local authority or retailer for recycling advice.
ISL-1857-00-022
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the Yale YDD424A and is the answer not in the manual?
Questions and answers