6) Installation Instructions (Rim and SecureBolt™)
6.1)
Verify hand and bevel of door. Door should be fitted and hung.
Verify box label for size of exit device, function and hand.
6.2)
Prep door according to supplied Corbin Russwin Inc. door marker template.
Hole for ribbon cable
1/8" Dia. holes
(2) required
Fire Stop Plate
Slot
Attach Fire Stop Plate
Using self tapping screws
#8x1/2" long for wood and
metal doors
Fire Rated Door
Install conduit half with recessed
panel "Not For Use On Fire Door"
visible from outside of door.
Inside
Left Hand
Reverse
Outside
"LHR"
Outside
of door
7/8"
Right Hand
Reverse
"RHR"
C of 1-1/2" Dia.
L
1-1/2"
Outside
of door
Non Fire Rated Door
5
Installation of the Conduit
(provided) is recommended when
the device is installed in a non fire
rated exterior door. The conduit is
part of a Weatherseal Gasketing Kit.
This kit can be ordered separately,
order part number 794F909.