Assa Abloy 9800 TCNE1 Series Installation Instructions Manual
Assa Abloy 9800 TCNE1 Series Installation Instructions Manual

Assa Abloy 9800 TCNE1 Series Installation Instructions Manual

With rim, securebolt, and mortise exit devices

Advertisement

Quick Links

Installation Instructions
for 9800 TCNE1 Series Trim by ED5200N (S) (A)
and 9M800 TCNE1 Series Trim by ED5600N (A) with
Rim, SecureBolt™, and Mortise Exit Devices
Please read these instructions carefully to prevent missing important Steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
Important:
The accuracy of the door preparation is critical for proper functioning and security of this trim.
Misalignment can cause premature wear and a lessening of security.
For installation assistance contact Corbin Russwin Inc. at 1-800-810-WIRE (9473).
1
2
3
4
5
6
7
8
9
*
0
#
FM242B 12/08 (617417610)
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR

Advertisement

Table of Contents
loading

Summary of Contents for Assa Abloy 9800 TCNE1 Series

  • Page 1 Installation Instructions for 9800 TCNE1 Series Trim by ED5200N (S) (A) and 9M800 TCNE1 Series Trim by ED5600N (A) with Rim, SecureBolt™, and Mortise Exit Devices FM242B 12/08 (617417610) Please read these instructions carefully to prevent missing important Steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty.
  • Page 2: Table Of Contents

    Table of Contents Page 1) Warning 2) General Description 3) Features / Specifications 4) Rim & SecureBolt™ TCNE1 Series Product Illustration 5) Switch Settings (Rim & SecureBolt™) 6) Installation Instructions 5 - 11 6.1) Before Starting 6.2) Attaching the Fire Stop Plate 6.3) Trim Assembly Instructions 6.4) Installation of Outside Trim and Exit Device 7 - 8...
  • Page 3: General Description

    2) General Descriptions General Description The Access 800 TCNE1 Rim, SecureBolt™ and Mortise Exit Device offers the ability to seamlessly ® integrate Grade 1 security into an existing Wiegand compatible access control system. Monitoring capabilities for Rim and SecureBolt include Request to Exit and Door Position Switch. Note: Mortise Exit devices offer Request to Exit and Door Position Switch and can monitor the latchbolt and/or Deadbolt of the Mortise Lock when connected to the Auxiliary Relay Module incorporated into the Network Interface Cabinet.
  • Page 4 4) 9800 TCNE1 Series Trim Product Illustration (Rim and SecureBolt™) SecureBolt™ Shown Inside Door 8 Pin Molex Doorwire Ground Wire 2 Pin Methode 2 Pin Solenoid Molex REX (2) Finish Washers (2) 1/4 - 20 Oval Head Screws Tailpiece must be...
  • Page 5 5) Switch Settings (Rim, SecureBolt™ and Mortise) Switch Settings This device has been shipped from the factory with switch settings configured as follows: Reader Dip-Switch Settings at Switch S1: Dip-Switch 4 – ON Solenoid Operation selected Dip-Switch 5 – ON or OFF based on Fail Safe or Fail Secure per order requirements Dip-Switch 6 –...
  • Page 6 6) Installation Instructions (Rim and SecureBolt™) 6.1) Verify hand and bevel of door. Door should be fitted and hung. Verify box label for size of exit device, function and hand. Inside Left Hand Right Hand Reverse Reverse Outside "LHR" "RHR" 6.2) Prep door according to supplied Corbin Russwin Inc.
  • Page 7 6) Installation Instructions (Rim and SecureBolt™) 6.3) heck cylinder components. NOTE: Cylinders longer than 1-1/8" (29mm) will require collars. Refer to Cylinder Collar Chart below. 2. When required, cut cylinder tailpiece. Correct length is 1/16" to 3/16" (2 to 5mm) beyond cylinder housing cam. 3.
  • Page 8: Trim Assembly Instructions

    6) Installation Instructions (Rim and SecureBolt™) 6.4) Installation of Outside Trim and Exit Device Outside Trim Assembly 1. For exterior door applications, it is recommended that the Trim Gasket (provided) be applied as shown below. 2. Route the 2 pin REX (Request to Exit) connector harness into the Trim Assembly cavity in the door and up thru the door and out the 1/2”...
  • Page 9 6) Installation Instructions (Rim and SecureBolt™) 6.4) Installation of Outside Trim and Exit Device Outside Trim Assembly 1. Seal device against door being careful to align vertical trim tailpiece to engage with cross hole of device cam. 2. Fasten device to trim assembly through holes “B” using (2) 1/4 – 20 pan head screws. 3.
  • Page 10: Installation Of Outside Keypad Escutcheon

    6) Installation Instructions (Rim and SecureBolt™) 6.5) Installation of Outside Keypad Escutcheon 1. For exterior door applications, it is recommended that the gaskets provided be applied as shown. The gaskets may be used as a seal between the escutcheon and the door surfaces. 2a.
  • Page 11: Installation Of Inside Controller Escutcheon And Electrical Connections

    6) Installation Instructions (Rim and SecureBolt™) 6.6) Installation of Inside Controller Escutcheon and Electrical Connections 1. For exterior door applications it is recommended that the gaskets provided be applied as shown. 2. Remove black cover from the escutcheon with High Security T20 Torx bit provided. 3.
  • Page 12: Cover Installation

    6) Installation Instructions (Rim and SecureBolt™) 6.7) Cover Installation 1. Attach cover to inside controller escutcheon making sure to line up tabs with retaining slots in the cover. Secure with security screw using T20 bit. C A U T I O N DOOR MUST REMAIN OPEN DURING INSTALLATION .
  • Page 13: Mortise Tcne1 Series Product Illustration

    7) 9M800 TCAC1 Series Trim Product Illustration (Mortise) 8 Pin Ground Molex Wire Doorwire 2 Pin Methode Solenoid 2 Pin Molex REX “A” “B” Solenoid Wire Harness “A” “B”...
  • Page 14: Before Starting

    7) Installation Instructions (Mortise) 7.1) Before Starting This device is handed because of the mortise lock and trim assembly being handed. Door should be fitted and hung. Verify box label for size of exit device, function and hand. Inside Left Hand Right Hand Reverse Reverse...
  • Page 15: Installation Of Mortise Lock

    7) Installation Instructions (Mortise) 7.3) Install Mortise Lock Feed Solenoid wire from Mortise Lock into Mortise cavity and up through the 1/2 diameter hole “C”. While sliding Mortise Case into door prep, pull the Solenoid wire from the Mortise Case out through “C” so that this wire does not get trapped behind the Mortise Case 3.
  • Page 16: Installation Of Outside Trim And Exit Device

    7) Installation Instructions (Mortise) 7.4) Installation of Outside Trim and Exit Device Outside Trim Assembly 1. For exterior door applications, it is recommended that the gaskets provided be applied as shown. 2. Route the 2 pin REX (Request to Exit) connector harness into the Trim Assembly cavity in the door and up thru the door and out the 1/2”...
  • Page 17 7) Installation Instructions (Mortise) 7.4) Installation of Outside Trim and Exit Device Exit Device 1. Seat device against door. NOTE: Device finger must engage latch bolt lever through slot in door and lock case/cover. 2. Fasten device to trim assembly through holes “B” using (2) 1/4 - 20 pan head screws.
  • Page 18: Installation Of Cylinder And Outside Keypad Escutcheon

    7) Installation Instructions (Mortise) 7.5) Installation of Cylinder and Outside Keypad Escutcheon Cylinder Installation Note: For devices without cylinders, skip this section. 1. Back cylinder set screw out of Mortise Lock. 2. Insert cylinder through trim assembly and thread into Mortise Lock until cylinder is flush with escutcheon.
  • Page 19: Installation Of Inside Controller Escutcheon And Electrical Connections

    7) Installation Instructions (Mortise) 7.6) Installation of Inside Controller Escutcheon and Electrical Connections 1. For exterior door applications it is recommended that the gaskets provided be applied as shown. 2. Remove black cover from the escutcheon with High Security T20 Torx bit provided. 3.
  • Page 20: Cover Installation

    6) Installation Instructions (Mortise) 7.7) Cover Installation 1. Attach cover to inside controller escutcheon making sure to line up tabs with retaining slots in the cover. Secure with security screw using T20 bit. C A U T I O N DOOR MUST REMAIN OPEN DURING INSTALLATION .
  • Page 21: Operational Check

    160 Four Valley Drive www.corbinrusswin.com Vaughan, ON L4K 4TG www.assaabloycanadadss.ca Copyright © 2008 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.

This manual is also suitable for:

9m800 tcne1 series

Table of Contents