ALLIANCE 120 Series Installation, Operation & Maintenance Manual page 77

120, 170, 200 series tumble dryers 54, 77 and 91 kilogram
Table of Contents

Advertisement

8. Immediately remove and weigh the load. Refer to
Table 20 for acceptable weight range. If less than
minimum pounds indicated in Table 20, the fire
suppression system has failed the maintenance
test. Refer to the Troubleshooting section.
IMPORTANT: If the fire suppression system failed
the maintenance test, DO NOT operate the tumble
dryer.
Dry Weight
kg
lbs.
120
27
60
34-36
170
36
80
43-45
200
45
100
52-54 115-119
Table 20
9. Clean up any water on the floor.
10. Electric Models Only: Run machine WITHOUT
HEAT for a minimum of 60 minutes before
continuing with steps 11-14.
11. Lock the fire suppression system control box.
12. If the separate alarm option is being used,
reconnect the auxiliary alarm output.
13. Start the tumble dryer to dry the test load.
14. On maintenance record, check box if fire
suppression system passed the test, date and sign
record.
70458101 (EN)
Minimum
Wet Weight
Weight
kg
lbs.
kg
lbs.
75-79
32
95-99
41
50
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
70
90
110
1
2
Spray Manifold
Water Spray
Figure 43
Maintenance
2
TMB2010N
TMB2010N
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

170 series200 seriesCa120lCa120nCk120nCt120l ... Show all