Before Placing Tumble Dryer Into Service - ALLIANCE 120 Series Installation, Operation & Maintenance Manual

120, 170, 200 series tumble dryers 54, 77 and 91 kilogram
Table of Contents

Advertisement

Installation
Before Placing Tumble Dryer into
Service
1. Remove or open all panels and check accessible
bolts, nuts, screws, terminals and fittings for
tightness.
2. Check V-belt tension and adjust if necessary.
Refer to Adjustments section.
3. Replace all panels and guards.
4. Turn on electrical supply to tumble dryer.
5. Open the supply valve for gas or steam heated
tumble dryers.
6. After performing the previous checks, start the
tumble dryer by pressing START. (Refer to the
Operating Section for detailed instructions.)
Release the start button and open the loading
door. The cylinder should stop rotating within
seven seconds after the door is opened.
7. Gas Tumble Dryers: Start the tumble dryer and
check the burner flame. Adjust the air inlet
shutter as required. Refer to Adjustments section.
IMPORTANT: The electronic ignition system will
attempt to light the gas by sparking for the "trial
for ignition" period. If gas does not ignite within
this period, the ignition control will go into a safety
lockout and the valve will no longer open until the
control is reset. It may be necessary to retry several
times to bleed air from the gas lines. To reset, open
and close the loading door and restart tumble
dryer.
24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Prepurge
Models
Time
(seconds)
18
CE and
Australia
1-3
All others
1
CE and
Australia
1
All others
Table 1
If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumble dryer from service.
8. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
Reset
Trial for
Lockout
Ignition
Condition
(seconds)
By:
10
025, 030,
035, 055:
Press reset
button on rear
of machine
T30, T45:
Press lighted
reset button
in rear
contactor box
10
Open loading
door
10
For models
(attempts to
with EO, RE,
ignite 3
RU or UO
times)
control
suffixes:
Press start on
control
keypad.
For models
with all other
control
suffixes:
Press and
hold reset
button on
junction box
until light
goes out.
10
Open loading
(attempts to
door
ignite 3
times)
70458101 (EN)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

170 series200 seriesCa120lCa120nCk120nCt120l ... Show all