Error Codes
Display
Open thermistor error
OP
Shorted thermistor error
SH
Airflow switch closed when cycle
AF - 1
started
Airflow switch failed to close after cycle
AF - 2
started
Bouncing Airflow Switch
AF
(Flashing)
Airflow Switch Closed when Resuming
AF
Cycle
(Solid)
70458101 (EN)
Definition
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Corrective Action
Check thermistor. Replace if inoperative.
Check wiring diagram between control and
thermistor. Refer to wiring diagram for proper
wiring.
Check control. Replace if inoperative.
Check thermistor. Replace if inoperative.
Check wiring between control and thermistor. Refer
to wiring diagram for proper wiring.
Check control. Replace if inoperative.
Check airflow switch. Replace if inoperative.
Check airflow switch. Replace if inoperative.
Check airflow switch to ensure that it is properly
aligned and securely mounted in the mounting
bracket.
Make sure airflow switch can open and close freely.
Check installation and make sure there is adequate
airflow.
Make sure exhaust is not blocked.
Clean the lint screen.
Replace airflow switch if inoperative.
Allow up to 20 seconds for this condition to clear.
Check if airflow switch opens at end of cycle.
Replace airflow switch if inoperative.
Operating Instructions
55