9. Check the airflow switch operation by opening
the lint panel; be sure to remove shipping tape
from airflow switch prior to operation.
Temporarily tape down the lint panel safety
switch located behind the upper left corner of the
lint panel. The heating systems should shut off
when the lint panel is opened a maximum of
152.4 mm (6 inches). The airflow switch
operation may be affected by lack of make-up air
or an obstruction in the exhaust duct. These
should be checked; if there is a problem, contact
an authorized service person.
WARNING
Do not operate tumble dryer if airflow
switch is faulty. An explosive gas mixture
could collect in tumble dryer if airflow
switch does not operate properly.
10. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution. Refer to
Figure 6.
IMPORTANT: The use of chlorine bleach for
removing any discoloration should be avoided
because bleach could damage the finish.
Figure 6
If the tumble dryer does not meet ANY of the listed
requirements, remove tumble dryer from use. Refer to
Removing Tumble Dryer from Service section.
70458101 (EN)
W407R1
T452I
T452I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Required for CE Models Only

Once machine is installed, please be sure to complete
the following items:
 Review and verify machine operation with
customer.
 Leave all literature and a signed Declaration of
Conformity with customer.
 Review machine warranty information with
customer.
 Apply warning sticker on front panel of machine,
in language appropriate to country of sale
(included in literature packet).