ALLIANCE 120 Series Installation, Operation & Maintenance Manual page 37

120, 170, 200 series tumble dryers 54, 77 and 91 kilogram
Table of Contents

Advertisement

J
I
CONTINUE
TO A
1
Outlet duct diameter
Duct
Stations
A
B
C
D
E
F
G
H
I
J
K
L
70458101 (EN)
L
K
TWO MANIFOLD ASSEMBLIES
120 Series
381 mm (15 in.)
533 mm (21 in.)
660 mm (26 in.)
762 mm (30 in.)
838 mm (33 in.)
914 mm (36 in.)
991 mm (39 in.)
1067 mm (42 in.)
1143 mm (45 in.)
1194 mm (47 in.)
1245 mm (49 in.)
1295 mm (51 in.)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
2
45° typical
Figure 14
170 Series
432 mm (17 in.)
610 mm (24 in.)
762 mm (30 in.)
864 mm (34 in.)
965 mm (38 in.)
1067 mm (42 in.)
1143 mm (45 in.)
1143 mm (45 in.)
1321 mm (52 in.)
1372 mm (54 in.)
1448 mm (57 in.)
1524 mm (60 in.)
Table 6
Exhaust Requirements
L
K
J
I
CONTINUE
2
TMB2018N
200 Series
432 mm (17 in.)
610 mm (24 in.)
762 mm (30 in.)
864 mm (34 in.)
965 mm (38 in.)
1067 mm (42 in.)
1143 mm (45 in.)
1143 mm (45 in.)
1321 mm (52 in.)
1372 mm (54 in.)
1448 mm (57 in.)
1524 mm (60 in.)
TO A
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

170 series200 seriesCa120lCa120nCk120nCt120l ... Show all

Table of Contents