3.3.3. Machine electrical connection
•
Disconnect and mechanically lock the external automatic switch.
•
Open machine terminal box at the rear panel. Remove the support cover of the entry switch to the washer.
•
On the entry hole of the electrical supply (E identified in figure 2) install a lock mechanism (not supplied
with the washer) to fasten the cable or cable pipe protector. Refer to dimensions and connection diameter
in INSTALLATION SPECS, section 1.4.
•
Connect the wires directly to the switch breaker.
•
The wire connection sequence to the main switch varies according to the machine connection and the
power supply. This connection is indicated on the label posted next to the main switch.
FOR A CORRECT CONNECTION, FOLLOW THE INDICATIONS LISTED IN THE TABLE BELOW
LABEL
POWER
SUPPLY
CONNECTION
PE/GND
PE/GND
L1
L2/N
L1
L2
Installation
PE/GND
L1
L2/N
L1
N
PE/GND
L1
L1
L2
L2
L3
L3
L1
L1
L2
L2
L3
L3
19
N
N
Cod. 429043