Machine Electrical Connection - GIRBAU HS-6008 Installation Manual

Table of Contents

Advertisement

Circuit breaker. Install an earth-leakage protected circuit breaker.
Characteristics:
Installed in an easily accessible place.
number of poles and intensity: consult ELECTRICAL CONNECTION table (section 1.5)
A type.
protected against pulse currents, harmonics, the presence of continuous components... (consult
manufacturer specifications)
Safety switch. Install an Automatic on/off Switch, outside the washer, with individual protection for each
machine.
Characteristics:
number of poles and intensity: consult ELECTRICAL CONNECTION table (section 1.5)
C type with top opening at 3 mm. (0.12 inch.)
Must isolate electrical source phases and the N cable.
Mechanically lockable.
Installed in an easily accessible place.

3.4.3. Machine electrical connection

Disconnect and mechanically interlock
external automatic switch.
Open machine terminal box.
Fix the electrical supply hose to the stuffing box
at the washer entry.
Connect the wires to the connection board.
The connection sequence of the cables to the
entry board varies according to the number of
phases and the voltage of the washer. On the
label posted next to the entry board are
indicated the different connection options. Refer
to fig. 19.
3.5. Electrical connection. 1ph, 120V units
with power cord (USA / CANADA only)
These models, available only for USA/CANADA installations are supplied with power cord built-in the
washer.
Connection characteristics
Connect to 15A mains outlet socket, Individual Branch Circuit.
Do not use any adaptor or extension cord between plug and socket.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for electric current. This appliance is equipped with a
cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING. Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly
grounded.
Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
Installation
the
20
fig. 19
Cod. 428938
Rev. 02/0512

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eh020

Table of Contents