3.4. Steam connection.

In some models the body of the steam electrovalve and the filter are shipped inside the drum of the
washing machine, separate from the electrical wiring system. The coil is connected to the end of the electrical
installation.
In other models, the assembly electrovalve and filter are supplied connected to the electrical wiring system.
Installation characteristics
Before connecting the installation to the electrovalve, purge the pipe conduits.
Place a mechanically lockable flow valve in the steam inlet in an accessible place.
Check dimensions and connection diameters in the Installation specs (section 1.4).
Assembly and electrovalve connection
SEAL ALL THREADED UNIONS WITH A PRODUCT WHICH IS APPROPRIATE FOR STEAM PIPE
CONDUITS.
Respect the steam circulation direction indicated by an arrow
on each part.
The coil has been previously removed from shipping position
or disconnected from the electrovalve (according to shipping
braces)
The electrical wiring must be fastened to the cut out VE on the
rear cover (see fig. 2 and section 2.4).
Place the electrovalve on the end of the steam inlet pipe of the
machine.
Machines in USA/Canada: place the small steam inlet hose
(fig.11/A) to the filter inlet.
Connect the steam supply of the installation to the washer inlet.
Safeguard the installation against accidental contact. It is
advisable to insulate the installation to prevent heat loss.
Place the coil on the electrovalve body and fasten it with the
core end screw.
Open the manual valve and check for leaks in the installation.