Technical description
6.2.1

Recommended torques

Connector
X3, X4
X10
X0
6.2.2

Fusing

Internal fusing
Circuit
Auxiliary supply 24V
Brake resistor
External fusing
Fusible cutouts or similar
(Fuse UL time delay)
AC supply
Type of branch circuit fuses:
Brake resistor F
* (x = S or S-R for 480V applications
Note:
6.2.3

Ambient conditions, ventilation, mounting position

Storage, hints
Transport, hints
Supply voltage tolerances
Ambient temperature in operation
Humidity in operation
Site altitude
Pollution level
Vibrations
Noise emission
Enclosure protection
Mounting position
Ventilation
Make sure that there is sufficient forced ventilation within the switchgear cabinet.
22
F
N1/2/3
Class RK5, 480V min
B1/2
The SERVOSTAR 640/670 drives are suitable for use on a circuit capable of delivering not more
than 42000rms symmetrical amperes, 480VAC max.
Input power (ð p.46)
Aux. power supply
12/2010
Recommended torque
0.3 Nm (2.25 in lb)
0,3 Nm (2.25 in lb)
6...8 Nm (45... 60 in lb)
SERVOSTAR 640
50 AT (FRx-50) *
x = N or N-R for 230V applications
ð p.15
ð p.15
min 3x230V
min 3x208V
24 VDC (-0% +15%), check voltage drop
o
0 to +45
+45 to +55°C (113 to 131 °F) with power derating
rel. humidity 85%, no condensation
up to 1000m a.m.s.l. without restriction
1000...2500m a.m.s.l. with power derating 1.5%/100m
Pollution level 2 to EN60204
Class 3M1 according to IEC 721-3-3
max. 45 dB(A)
IP 20 according to EN 60529
generally vertical. ð p.34
forced convection by built-in fans
®
SERVOSTAR
Internal fuse
4 AT
electronic
SERVOSTAR 670
80 AT (FRx-80) *
KLM 20
ð p. 10)
AC / max 3x 480V
-10%
AC / max 3x 480V
-10%
C (32 to 113 °F) at rated data
640/670 Instructions Manual
Kollmorgen
KLM 30
+10%
, 50 Hz
+10%
, 60 Hz
2.5% / K

Hide quick links: