Guide To Electrical Installation - Kollmorgen SERVOSTAR 640 Instruction Manual

Digital servo amplifier
Table of Contents

Advertisement

Electrical Installation
8.2

Guide to electrical installation

The following notes should assist you to carry out the electrical installation in a sensible sequence,
without overlooking anything important.
Cable selec-
Grounding
Final check
38
Select cables according to EN 60204 (ð p. 23)
tion
EMC-compliant (EMI) shielding and grounding (ð p. 45)
Earth (ground) the mounting plate, motor housing and CNC-GND of the controls.
Shielding
Notes on connection techniques are on page 40
Route power leads and control cables separately
Wiring
Wire the BTB/RTO contact in series into the emergency stop
circuit of the system.
— Connect the digital control inputs to the servo amplifier
— Connect up AGND (also if fieldbuses are used)
— Connect the analog setpoint, if required
— Connect up the feedback unit (resolver and/or encoder)
— Connect the encoder emulation, if required
— Connect the expansion card (see corresponding manual on the CD-ROM)
— Connect the motor cables, connect shielding to EMI connectors at both ends
— Connect motor-holding brake, connect shielding to EMI connectors at
both ends
— Connect the external regen resistor (with fusing)
— Connect aux. supply (for max. permissible voltage values ð p. 22)
— Connect mains choke and mains filter (shielded lines between filter and
servo amplifier)
— Connect main power supply (for max. permissible voltage values ð p. 22)
— Connect PC (ð p. 68).
— Final check of the implementation of the wiring,
according to the wiring diagrams which have been used.
12/2010
®
SERVOSTAR
640/670 Instructions Manual
Kollmorgen

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Servostar 670

Table of Contents