Technical Description - Kollmorgen SERVOSTAR 640 Instruction Manual

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
6

Technical description

6.1
The digital servo amplifiers of the series SERVOSTAR 640/670
Standard version
l
l
l
l
l
l
l
l
l
Power supply
l
l
l
l
l
l
l
l
External interference suppression filter for the supply input (to category C2)
required. External mains choke required.
Integrated safety
l
l
l
Auxiliary supply voltage 24VDC
l
®
SERVOSTAR
640/670 Instructions Manual
2 current ratings (40 A, 70 A)
Wide range of rated voltage (3x208V
Overvoltage category III acc. to EN 61800-5-1
Shield connection directly at the servo amplifier
Integrated CANopen (default 500 kBaud), for integration into CANbus systems and for
setting parameters for several amplifiers via the PC-interface of one amplifier
Integrated RS232, electrically isolated, integrated pulse-direction interface
-AS-
built-in safety relay (personnel-safety starting lock-out), (ð p.70)
Slot for an expansion card
Synchronous servomotors, linear motors and asynchronous motors can be used
With external mains filter and mains choke directly off grounded 3~ system,
+10%
230V
... 480V
-10%
+10%
208V
... 480V
-10%
TN-system, TT-system with earthed (grounded) neutral point, not more than 42,000 rms
symmetrical amperes, 480VAC maximum; when protected by fuses type Fusetron FRS-R-80
(Class RK5), manufactured by Bussman, or equivalent 480VAC min
Connection to other mains supply networks only with insulating transformer ð p. 46
BB6 rectifier bridge, off 3-phase earthed (grounded) supply, integral inrush circuit
Fusing (e.g. fusible cutout) provided by the user
All shielding connections directly on the amplifier
Output stage: IGBT- module with isolated current measurement
Brake circuit: with dynamic distribution of the brake power between several
amplifiers on the same DC bus link circuit, external brake resistor
DC bus link voltage 260 ... 900 VDC, can be switched in parallel
Interference suppression filter for the 24V aux. supply (to category C2) is integrated
Safe electrical separation between the power input / motor connections and the signal elec-
tronics, provided by appropriate insulation/creepage distances and complete electrical isola-
tion
Soft-start, overvoltage recognition, short-circuit protection, phase-failure monitoring
Temperature monitoring of servo amplifier and motor
(when using our motors with our pre-assembled cables)
Electrically isolated, internal fusing, from an external 24VDC psu, e.g. with isolating transfor-
mer
12/2010
to 3x480V
–10%
, 50 Hz,
, 60 Hz,
Technical description
+10%
)
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Servostar 670

Table of Contents