Kollmorgen
8.3.3
Technical data for cables
Further information on the chemical, mechanical and electrical characteristics of the cables can be
obtained from out customer service .
Observe the restrictions in the chapter "Conductor cross-sections" on page 23.
To operate the amplifier with the max. permitted cable length, you must use cable
material which meets the requirements on the capacity given below.
Insulation material
Sheathing
Core insulation
Capacitance
Motor cable
Feedback cable
Technical data
For a detailed description of cable types and how to assemble them, please refer to the accessories
manual.
®
SERVOSTAR
640/670 Instructions Manual
12/2010
PUR (polyurethane, code 11Y)
PETP (polyesteraphtalate, code 12Y)
£ 4mm² : less than 150 pF /m
>4mm² : less than 250 pF/m
less than 120 pF/m
Electrical Installation
41