Connector Assignments - Kollmorgen SERVOSTAR 640 Instruction Manual

Digital servo amplifier
Table of Contents

Advertisement

Kollmorgen
10.2.5

Connector assignments

Connector X11A
Terminal
Connector X11B
®
SERVOSTAR
640/670 Instructions Manual
Dir
Function
1
In
A0
2
In
A1
3
In
A2
4
In
A3
5
In
A4
6
In
A5
7
In
A6
8
In
A7
9
In
Reference
10
In
FError_clear
11
In
Start_MT Next
12
In
Start_Jog v=x
1
In
MT_Restart
2
In
Start_MT I/O
3
Out
InPos
Next-InPos
4
Out
PosReg0
5
Out
FError
6
Out
PosReg1
7
Out
PosReg2
8
Out
PosReg3
9
Out
PosReg4
10
Out
PosReg5
11
Supply
24VDC
12
Supply
I/O-GND
12/2010
Description
Motion task no., LSB
1
Motion task no., 2
2
Motion task no., 2
3
Motion task no., 2
4
Motion task no., 2
5
Motion task no., 2
6
Motion task no., 2
Motion task no., MSB
Polls the reference switch. If a digital input on the basic unit
is used as a reference input, then the input on the I/O expan-
sion card will not be evaluated.
Clear the warning of a following error or the response moni-
toring.
The following task, that is defined in the motion task by "Start
with I/O" is started. The target position of the present motion
task must be reached before the following task can be start-
ed. The next motion block can also be started by an appro-
priately configured digital input on the basic unit.
Start of the setup mode "Jog Mode" with a defined speed. Af-
ter selecting the function, you can enter the speed in the au-
xiliary variable "x". The sign of the auxiliary variable defines
the direction. A rising edge starts the motion, a falling edge
cancels the motion.
Continues the motion task that was previously interrupted.
The motion task can also be continued by an appropriately
configured digital input on the basic unit.
Start of the motion task that has the number that is presen-
ted, bit-coded, at the digital inputs (A0 to A7).
The digital function with the same name, in the basic unit,
starts the motion task with the address from the digital inputs
on the basic unit.
When the target position for a motion task has been reached
(the InPosition window), this is signalled by the output of a
HIGH-signal.
A cable break will not be detected
The start of each motion task in an automatically executed
sequence of motion tasks is signalled by an inversion of the
output signal. The output produces a Low signal at the start
of the first motion task of the motion task sequence.
The form of the message can be varied by using ASCII com-
mands.
Can only be adjusted by ASCII commands.
Following-error (low-active).
The preset function of the corresponding position register is
indicated by a HIGH-signal.
Can only be adjusted by ASCII commands.
auxiliary supply voltage
Digital-GND for the controls
Expansion Cards
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Servostar 670