SMC Networks HRS100-A?-20-? Operation Manual page 177

Thermo chiller
Hide thumbs Also See for HRS100-A?-20-?:
Table of Contents

Advertisement

8.1.3
HRS100/150-W∗-20-∗
Model
Cooling method
Refrigerant
Control method
∗ 1
Ambient temperature
Circulating fluid
Operating temperature range
Cooling capacity 50/60Hz
Heating capacity
Temperature stability
Rated
50/60Hz (Outlet)
Pump
Maximum flow rate
capacity
50/60Hz
Maximum
height
Minimum operating flow rate
Circulating
∗ 7
50/60Hz
fluid
Tank capacity
system
Circulating fluid outlet, circulating fluid
return port
Pump drain port
Automatic
fluid fill
function
(Standard)
Wetted material
Temperature range
Pressure range
Required flow
∗ 5
50/60Hz
Facility
Facility
water
water
differential
system
Facility water inlet, outlet port
Wetted material
Power supply
Recommended
earth
leakage
Electric
∗ 8
breaker
system
Rated operating current
∗ 5
50/60Hz
Rated power consumption
∗ 5
50/60Hz
Sound level (F
ront 1m / Height 1m)
Water-proof specification
Accessory
Weight (dry condition)
∗1 Use 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. or ambient temperature is lower than
o
10
C. Please discharge the facility water from the facility water circuit when there is a risk of freezing.
∗2 Use fluid in condition below as the circulating fluid.
Tap water: Standard of The Japan Refregeration And Air Conditioning Industry Association (JRA GL-02-1994)
15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Deionized water: Conductivity 1μS/cm and higher (electrical resistivity 1MΩ・cm and lower)
∗3 (1)Facility water temp.: 32
rate, (5)Power supply: AC200V
∗4 (1)Facility water temp.: 32
∗5 (1) Facility water temp .: 32
capacity, (5)Circulating fluid flow rate: Rated flow rate, (6)Power : AC200V, (7)External piping length: Minimum
∗6
When circulating fluid outlet port pressure – return port pressure = 0.25MPa.
∗7
Fluid flow rate to maintain the cooling capacity and to keep the circulating fluid discharge puressure to 0.5MPa or less. If the actual flow
rate is lower than this, please install a bypass piping.
∗8 To be prepared by the customer. A specified earth leakage breaker is installed for option B [Earth leakage breaker] of each model.
HRS Series
Table 8-3 Specifications[HRS100/150-W∗-20-∗]
o
C
∗ 2
∗ 1
o
C
∗ 3
kW
∗ 4
kW
∗ 5
o
C
flow
rate
L/min
∗ 6
L/min
lifting
m
L/min
L
Supply
side
MPa
press. range
Supply
side
o
C
fluid temp.
Automatic fluid fill port
Over flow port
PTFE, PU, EPDM, PVC, NBR, PE, NR, PBT, POM, PP, Carbon, Ceramic
o
C
MPa
L/min
pressure
MPa
Rated
A
current
Sensitivity
mA
A
kW (kVA)
∗ 5
dB(A)
Y strainer (40 mesh) 20 A 1pc., Barrel nipple 20 A 1pc. Drain pan for the pump 1pc.
kg
o
C, (2)Circulating fluid : Tap water, (3)Circulating fluid temp.: 20
o
C, (2)Circulating fluid : Tap water, (3) Circulating fluid flow rate : Rated flow rate, (4)Power supply: AC200V
o
C, (2)Circulating fluid : Tap water, (3)Circulating fluid temp.: 20
HRS100-W∗-20-∗
Water-cooled refrigerated type
Tap water, Ethylene glycol aqueous solution 15%, Deionized water
10.0 / 11.0
1.7 / 2.2
Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4)
Rc1/4 (Symbol F: G1/4, Symbol N: NPT1/4)
Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2)
Rc1 (Symbol F: G1, Symbol N: NPT1)
Stainless, Cupper(Heat exchanger brazing), Brass, Bronze
33 / 34
Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4)
Stainless, Cupper(Heat exchanger's brazing ), Bronze, Brass
PTFE, NBR, EPDM
AC200/200-230V 50/60Hz 3phase
Allowable voltage fluctuation ±10% (No continuous voltage fluctuation)
30
13 / 14
3.4 / 4.4
(4.4 / 5.0)
Alarm cord list label 2pc.(English 1pc./Japanese 1pc.),
Operation manual 2pc. (English 1pc./Japanese 1pc.),
151
Chapter 8
HRS150-W∗-20-∗
R410A (HFC)
PIDcontrol
2 to 45
5 to 35
14.5 / 16.5
2.5 / 3.0
±1.0
42 / 56
55 / 68
50
28 / 42
18
0.2 to 0.5
5 to 35
5 to 40
0.3 to 0.5
38 / 40
More than 0.3
40
30
16 / 19
4.6 / 6.0
(5.6 / 6.6)
70
IPX4
154
o
C, (4)Circulating fluid flow rate : Rated flow
o
C, (4)Heat load : Same as the cooling
8.1 Specifications
HRX-OM-S004
Documents
8-3