SMC Networks HRS100-A?-20-? Operation Manual page 141

Thermo chiller
Hide thumbs Also See for HRS100-A?-20-?:
Table of Contents

Advertisement

22.
Perform setting for parity check (simple communication protocol) with [▲] key or [▼]
key, and press [SEL] key to enter.
Set value
Setting/Checking: Stop bit (simple communication protocol)
23.
Press the [SEL] key once.
Setting screen of stop bit (simple communication protocol) is displayed on the digital
display.
PV
SV
24.
Set stop bit (simple communication protocol) with [▲] key or [▼] key, and press [SEL]
key to enter.
Set value
Setting/Checking: Response delay time (simple communication protocol)
25.
Press the [SEL] key once.
Setting screen of response delay time (simple communication protocol) is displayed on
the digital display.
PV
SV
HRS Series
Table 5.21-12 Parity check setting
Explanation
Setting/checking is possible only when the
serial
protocol
setting
communication protocol.
No parity check
Parity check with odd number
Parity check with even number
Table 5.21-13 Stop bit setting
Explanation
Setting/checking are not available unless the
serial
protocol
setting
communication protocol.
1 bit
2 bit
Chapter 5
Display and setting of various functions
is
simple
is
simple
HRX-OM-S004
Initial value
(Default setting)
Initial value
(Default setting)
5.21Communication function
5-75