SMC Networks HRS100-A?-20-? Operation Manual page 176

Thermo chiller
Hide thumbs Also See for HRS100-A?-20-?:
Table of Contents

Advertisement

HRX-OM-S004
Chapter 8
Documents
8.1.2
HRS100/150-A∗-40-∗
Model
Cooling method
Refrigerant
Control method
∗ 1
Ambient temperature
Circulating fluid
Operating temperature range
Cooling capacity 50/60Hz
Heating capacity
Temperature stability
Rated
50/60Hz (Outlet)
Pump
Maximum flow rate
capacity
50/60Hz
Maximum
height
Minimum operating flow rate
Circulating
∗ 7
50/60Hz
fluid
Tank capacity
system
Circulating fluid outlet, circulating fluid
return port
Pump drain port
Automatic
fluid fill
function
(Standard)
Wetted material
Power supply
Earth
leakage
breaker
Electric
(Standard)
system
Rated operating current
∗ 5
50/60Hz
Rated power consumption
∗ 5
50/60Hz
Sound level (F
ront 1m / Height 1m)
Water-proof specification
Accessory
Weight (dry condition)
Compliance
CE Marking
standard
∗1 Use 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. or ambient temperature is lower than
o
10
C
∗2 Use fluid in condition below as the circulating fluid.
Tap water: Standard of The Japan Refregeration And Air Conditioning Industry Association (JRA GL-02-1994)
15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Deionized water: Conductivity 1μS/cm and higher (electrical resistivity 1MΩ・cm and lower)
∗3 (1)Operating ambient temp.: 32
flow rate, (5)Power supply: AC400V
∗4 (1)Operating ambient temp.: 32
AC400V
∗5 (1)Operating ambient temp.: 32
capacity, (5)Circulating fluid flow rate: Rated flow rate, (6)Power : AC400V, (7) External piping length: Minimum.
∗6
When circulating fluid outlet port pressure – return port pressure = 0.25MPa.
∗7
Fluid flow rate to maintain the cooling capacity and to keep the circulating fluid discharge puressure to 0.5MPa or less. If the actual flow rate is lower than this,
please install a bypass piping.
8.1 Specifications
8-2
Table 8-2 Specifications [HRS100/150-A∗-40-∗]
o
C
∗ 2
∗ 1
o
C
∗ 3
kW
∗ 4
kW
∗ 5
o
C
flow
rate
L/min
∗ 6
L/min
lifting
m
L/min
L
Supply
side
MPa
press. range
Supply
side
o
C
fluid temp.
Automatic fluid fill port
Over flow port
PTFE, PU, EPDM, PVC, NBR, PE, NR, PBT, POM, PP, Carbon, Ceramic
Rated
A
current
Sensitivity
mA
A
kW (kVA)
∗ 5
dB(A)
kg
EMC directive
Machinery directive
o
C, (2)Circulating fluid : Tap water, (3)Circulating fluid temp.: 20
o
C, (2)Circulating fluid : Tap water, (3) Circulating fluid flow rate : Rated flow rate, (4)Power supply:
o
C, (2)Circulating fluid : Tap water, (3)Circulating fluid temp.: 20
HRS100-A∗-40-∗
Air-cooled refrigerated type
Tap water, Ethylene glycol aqueous solution 15%, Deionized water
9.0 / 9.5
1.7 / 2.2
Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4)
Rc1/4 (Symbol F: G1/4, Symbol N: NPT1/4)
Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2)
Rc1 (Symbol F: G1, Symbol N: NPT1)
Stainless, Cupper(Heat exchanger brazing), Brass, Bronze
AC380-415V 50/60Hz 3phase
Allowable voltage fluctuation ±10% (No continuous voltage fluctuation)
6.9 / 7.5
3.7 / 4.7
(4.7 / 5.3)
70
Alarm cord list label 2pc.(English 1pc./Japanese 1pc.),
Operation manual 2pc. (English 1pc./Japanese 1pc.),
Y strainer (40 mesh) 20 A 1pc., Barrel nipple 20 A 1pc.
Drain pan for the pump 1pc.
171
HRS150-A∗-40-∗
R410A (HFC)
PIDcontrol
-5 to 45
5 to 35
13.0 / 14.5
2.5 / 3.0
±1.0
42 / 56
55 / 68
50
28 / 42
18
0.2 to 0.5
5 to 35
20
30
8.1 / 9.6
4.8 / 6.1
(5.7 / 6.6)
72
IPX4
177
2004/108/EC
2006/42/EC
o
C, (4)Criculating fluid flow rate : Rated
o
C, (4)Heat load : Same as the cooling
HRS Series