4.4.2 Factory reset

The external relay and alarm cable shield
must be earthed.
To restore the factory default settings connect the
contacts as shown in figure (Reset, COM).
Reset
COM
Fig. 2

4.5 Washing system connection

For further details on configuration and
use, refer to the relative manual: HEPWS

4.6 Hardware configuration

It is not necessary to configure the device
communication protocol.
6

5 Switching on

The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
depending on environmental conditions
(from 30 minutes up to 90 minutes).
Complete functionality of the product is guaranteed
up to the following ambient temperature: -40°C(cold
start), -50°C(running).
The product is equipped with a firmware protection
that deactivates the video camera in temperatures of
below -40°C (cold start), -50°C (running).
The unit is switched on by connecting the power
supply.
To switch off the unit disconnect the power.

5.1 First start-up

Make sure that the unit and other
components of the installation are closed
so that it is impossible to come into contact
with live parts.
Make sure that all parts are fastened down
firmly and safely.
Document 800-23092 Rev. A