Main Data And Specifications - Isuzu Trooper 1999 Workshop Manual

Trooper 1999
Table of Contents

Advertisement

1A–66 HEATING, VENTILATION AND AIR CONDITIONING (HVAC)

Main Data And Specifications

General Specifications
HEATER UNIT
Temperature control
Capacity
Air flow
HEATER CORE
Type
Element dimension
Radiating area
EVAPORATOR ASSEMBLY
Capacity
Air flow
EVAPORATOR CORE
Type
Element dimension
EXPANSION VALVE
Type
THERMOSTAT SWITCH
Type
CONDENSER
Type
Radiation performance
RECEIVER/DRIER
Type
Internal volume
PRESSURE SWITCH
Type
REFRIGERANT
Type
Specified amount
Reheat air mix system
3,700 Kcal./hr.
280 m#/hr
Plate and corrugate fin type
171 mm (6.7 in.)
161 mm (6.3 in.)
Approx. 0.75 m@
4,200 Kcal./hr.
470 m#/hr
Al-laminate louver fin type
235 mm (9.3 in.)
225.3 mm (8.9 in.)
Internal pressure equalizer type
Electronic thermostat
0.5 °C (38.3
OFF: Below 3.5
0.5 °C (41.0
ON: Above 5.0
Parallel flow
13,700 Kcal./hr
Assembly includes sight glass with dual pressure
switch
300 cc (10 fl.oz.)
Dual pressure switch
Low pressure control
ON: 186.3 29.4 kPa (27.0 4.3 psi)
OFF: 176.5 19.6 kPa (25.6 2.8 psi)
High pressure control
DIFF: 2353.6 196.1 kPa (341.3 28.4 psi)
OFF: 2942.0 196.1 kPa (426.6 28.4 psi)
HFC-134a
600 g (1.32 lbs.)
25 mm (0.98 in.)
60 mm (2.4 in.)
0.9 °F)
0.9 °F)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trooper ux 1999

Table of Contents