Check clearance between capsule and bracket. It must
be within 1 mm (0.039 in).
Column Tube
Check for collapse by measuring the distance as shown in
the figure.
Standard distance: 162.2–165.8 mm (6.386–6.528
in)
Column Universal Joint for Tilt Mechanism
If the resistance is felt when checked by rotate the joint,
replace the steering column assembly.
POWER ASSISTED SYSTEM
Sheared Injected Plastic Pin
Check the sheared injected plastic pins for any loose
conditions or damage.
431RW031
Shaft Length
Check the shaft length from the upper end of the slide joint
to the end of the shaft. If column length is not in
specifications, steering column should be replaced.
Standard length: 308–310 mm (12.126–12.205 in)
431RW032
Shaft Universal Joint (Lower End)
If the resistance is felt when checked by rotate the joint,
replace the steering column assembly.
Shaft Bellows Pipe
Check the shaft bellows pipe for bend by using straight
edge. Measure the clearance between the bellows pipe
and the straight edge (at center of the bellows pipe).
Standard: Less than 1 mm (0.039 in)
2A–61
431RW033
431RX003