Safety Switch; Starter And Starter Relay - Kubota L3200 Workshop Manual

Hide thumbs Also See for L3200:
Table of Contents

Advertisement

L3200, WSM

(3) Safety Switch

(4) Starter and Starter Relay

Safety Switch Continuity
1. Remove the safety switch leads.
2. Connect the circuit tester to the safety switch leads.
3. Measure the resistance between leads.
4. If the safety switch is defective, replace it.
When switch push is
pushed
Resistance (Across
switch terminal)
When switch push is
released
(1) Safety Switch for PTO Gear Shift
Lever
Starter Motor B Terminal Voltage
1. Measure the voltage across the B terminal and chassis.
2. If the voltage differs from the battery voltage, check the battery's
cable.
Voltage
Factory spec.
Motor Test
CAUTION
• Secure the starter to prevent it from jumping up and down
while testing the motor.
1. Disconnect the battery negative cable from the battery.
2. Disconnect the battery positive cable and the leads from the
starter.
3. Remove the starter from the engine.
4. Remove the connecting lead (2) from the starter C terminal (1).
5. Connect a jumper lead from the connecting lead (2) to the battery
positive terminal post.
6. Connect a jumper lead momentarily between the starter motor
housing and the battery negative terminal post.
7. If the motor does not run, check the motor.
(1) C Terminal
9-S10
ELECTRICAL SYSTEM
0 Ω
Infinity
(2) Safety Switch for Range Gear Shift
Lever
W10385250
Approx. battery voltage
W10396300
(1) Connecting Lead
W10398570
KiSC issued 12, 2006 A